文献速递神经肿瘤

术中近红外光学对比可定位脑转移瘤

Intraoperative Near-Infrared Optical Contrast Can Localize Brain Metastases.
PubMed 文献 · World Neurosurg · 2017-06-30

研究纳入13例脑实质内脑转移瘤患者,术前一日按5 mg/kg给予吲哚菁绿,术中使用近红外相机成像。所有13处转移瘤均发出荧光,平均信号背景比6.62,肿瘤标本平均信号背景比6.9,非肿瘤标本为3.7,灵敏度96.4%、特异度27.3%。

要点

  • 术前一日按5 mg/kg给予吲哚菁绿,13处脑转移瘤均可在术中近红外成像中显影。
  • 肿瘤标本平均信号背景比6.9,非肿瘤标本为3.7。
  • 近红外成像灵敏度96.4%、特异度27.3%,切缘评估受假阳性率高限制。

核心结论

  • 第二窗口吲哚菁绿(SWIG)可提供强的近红外光学对比,用于硬脑膜打开前定位肿瘤。
  • SWIG用于切缘评估仍受特异度不足(假阳性率高)限制,但影像参数改进有望减少假阳性结果。

研究设计与样本

  • 13例脑实质内脑转移瘤患者术前一日按5 mg/kg给予吲哚菁绿,术中使用近红外相机识别肿瘤并检查手术切缘,以神经病理评估荧光染料识别肿瘤的准确性与精确性。

主要发现

  • 吲哚菁绿在显影前24.7 ± 3.45小时输注,13处转移瘤均发出荧光,平均信号背景比(SBR)为6.62。
  • 硬脑膜完整时SBR为硬脑膜打开后平均SBR的67.2%,近红外信号可透过正常脑实质达7 mm。
  • 39份标本中,肿瘤标本(n = 28)平均SBR为6.9,非肿瘤标本(n = 11)平均SBR为3.7。
  • 近红外成像识别肿瘤的灵敏度为96.4%、特异度为27.3%、阳性预测值为77.1%、阴性预测值为75.0%。

临床怎么用

  • 作者认为SWIG可提供强的近红外光学对比,用于硬脑膜打开前定位肿瘤。
  • 作者指出SWIG用于切缘评估仍受特异度不足(假阳性率高)限制,影像参数改进有望减少假阳性结果。

局限性

  • SWIG用于切缘评估仍受特异度不足(假阳性率高)限制。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Approximately 100,000 brain metastases are diagnosed annually in the United States. Our laboratory has pioneered a novel technique, second window indocyanine green (SWIG), which allows for real-time intraoperative visualization of brain metastasis through normal brain parenchyma and intact dura. METHODS: Thirteen patients with intraparenchymal brain metastases were administered indocyanine green (ICG) at 5 mg/kg the day before surgery. A near-infrared (NIR)- capable camera was used intraoperatively to identify the tumor and to inspect surgical margins. Neuropathology was used to assess the accuracy and precision of the fluorescent dye for identifying tumor. RESULTS: ICG was infused at 24.7 ± 3.45 hours before visualization. All 13 metastases fluoresced with an average signal-to-background ratio (SBR) of 6.62. The SBR with the dura intact was 67.2% of the mean SBR once the dura was opened. The NIR signal could be visualized through normal brain parenchyma up to 7 mm. For the 39 total specimens, the mean SBR for tumor specimens (n = 28) was 6.9, whereas the SBR for nontumor specimens (n = 11) was 3.7. The sensitivity, specificity, positive predictive value, and negative predictive value of NIR imaging for tumor was 96.4%, 27.3%, 77.1%, and 75.0%. DISCUSSION: SWIG relies on the passive accumulation of dye in abnormal tumor tissue via the enhanced permeability and retention effect. It provides strong NIR optical contrast, which can be used to localize tumors before dural opening. The use of SWIG for margin assessment remains limited by its lack of specificity (high false-positive rate); however, ongoing improvements in imaging parameters show great potential to reduce false-positive results.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Lee JYK, Pierce JT, Zeh R, et al. Intraoperative Near-Infrared Optical Contrast Can Localize Brain Metastases. World Neurosurg. 2017. PMID: 28669877. doi:10.1016/j.wneu.2017.06.128

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。