文献速递神经重症神经创伤

急性脑损伤合并PaO2/FiO2降低患者经皮扩张气管切开术的安全性——54例回顾性分析

Safety of Percutaneous Dilatational Tracheostomy in Patients with Acute Brain Injury and Reduced PaO2/FiO2 Ratio-Retrospective Analysis of 54 Patients.
PubMed 文献 · World Neurosurg · 2017-05-31

回顾性分析54例急性脑损伤合并PaO2/FiO2<300 mmHg患者,经皮扩张气管切开术(PDT)术中低氧血症2例(3.6%)、高碳酸血症4例(7.4%),低氧血症仅见于ARDS组(2/20);作者认为仅PaO2/FiO2降低时PDT似乎安全,但合并ARDS时应谨慎考虑指征。

要点

  • 54例急性脑损伤合并PaO2/FiO2<300 mmHg患者行PDT,术中低氧血症2例(3.6%)、高碳酸血症4例(7.4%)。
  • 20例符合柏林标准ARDS,术中低氧血症仅见于ARDS组(2/20)。
  • 全部患者平均PaO2/FiO2由PDT前229.1 mmHg改善至255.3 mmHg。

核心结论

  • 就术中气体交换而言,急性脑损伤合并ARDS患者行PDT的指征应谨慎考虑;而仅PaO2/FiO2降低的急性脑损伤患者行PDT似乎是安全的手术。

研究设计与样本

  • 回顾性分析纳入54例急性脑损伤且PaO2/FiO2<300 mmHg的患者,全部病例均有PDT前、术中及约12小时后血气分析,并复习呼吸机设置、气体交换结果及急性呼吸窘迫综合征(ARDS)的影像学征象,ARDS按柏林标准定义。

主要发现

  • 术中低氧血症(PaO2<60 mmHg)2例(3.6%),术中高碳酸血症(PaCO2>55 mmHg)4例(7.4%)。
  • 20例符合柏林标准ARDS;ARDS组与非ARDS组平均PaO2无显著差异,术中低氧血症仅见于ARDS组(2/20)。
  • ARDS组与非ARDS组平均PaCO2相似,两组均出现高碳酸血症病例。
  • 全部患者平均PaO2/FiO2由PDT前229.1 mmHg改善至255.3 mmHg。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Percutaneous dilatational tracheostomy (PDT) is a commonly performed method in neurocritical care, and its safety has been proven in numerous studies. Nevertheless, data regarding the application in patients with acute brain injury and poor respiratory function are poor. The purpose of this study was to evaluate the incidence of hypoxemia and hypercapnia during PDT in those patients. METHODS: In a retrospective analysis, we acquired data from 54 patients with an acute brain injury (ABI) and a reduced PaO2/FiO2 ratio (PaO2/FiO2 < 300 mm Hg). In all cases, blood gas analyses before, during, and approximately 12 hours after PDT were available. We reviewed the patients' ventilator settings, results of gas exchange, and radiographic signs of acute respiratory distress syndrome (ARDS). Patients with ARDS were defined using the Berlin criteria. RESULTS: We observed 2 cases (3.6%) of intraoperative hypoxemia (PaO2 < 60 mm Hg) and 4 cases (7.4%) of intraoperative hypercapnia (PaCO2 > 55 mm Hg). Twenty patients fulfilled the Berlin criteria for ARDS. While mean PaO2 did not differ significantly between ARDS and non-ARDS patients, intraoperative hypoxemia only occurred in the ARDS group (2/20). Mean PaCO2 was similar in the ARDS and non-ARDS groups, and cases of hypercapnia were apparent in both groups. The mean PaO2/FiO2 ratio of all patients improved from 229.1 mm Hg before PDT to 255.3 mm Hg. CONCLUSIONS: Regarding the intraoperative gas exchange, indication of PDT in patients with ABI and ARDS should be considered carefully. However, PDT in ABI patients with reduced PaO2/FiO2 ratio alone appears to be a safe procedure.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Ditz C, Wojak JF, Smith E, et al. Safety of Percutaneous Dilatational Tracheostomy in Patients with Acute Brain Injury and Reduced PaO2/FiO2 Ratio-Retrospective Analysis of 54 Patients. World Neurosurg. 2017. PMID: 28578113. doi:10.1016/j.wneu.2017.05.127

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。