文献速递功能神经外科

药物难治性癫痫中岛叶立体定向脑电图电极植入的适应证、技术与安全性

Indications, technique, and safety profile of insular stereoelectroencephalography electrode implantation in medically intractable epilepsy.
PubMed 文献 · J Neurosurg · 2017-06-16

该研究回顾了2009年6月至2013年4月间198例连续接受立体定向脑电图(SEEG)植入的患者,其中135例疑似岛叶癫痫患者共植入303根岛叶电极。23例(17.04%)经SEEG确认岛叶为发作起始区,无岛叶电极相关脑出血。岛叶切除术后Engel I级5例(33.3%)。作者认为岛叶探查安全,正交电极用于岛盖受累假设,斜向电极可提高岛叶采样率。

要点

  • 135例疑似岛叶癫痫患者植入303根岛叶电极,无岛叶电极相关脑出血。
  • 23例(17.04%)经SEEG确认发作起始区位于岛叶。
  • 岛叶切除术后Engel I级5例(33.3%),II级6例(40%)。

核心结论

  • 作者认为,使用立体定向放置的深部电极探查岛叶是一项安全的技术。
  • 当假设提示岛盖受累时植入正交电极;而斜向电极允许更高的岛叶采样率。

研究设计与样本

  • 回顾性分析2009年6月至2013年4月间198例连续接受SEEG植入(共1556根电极)的药物难治性癫痫患者。
  • 根据发作症状学、头皮脑电图及术前影像(MRI、PET、SPECT或脑磁图)识别疑似岛叶受累患者。
  • 纳入术后CT与术前MRI融合三维重建显示至少1根岛叶电极的患者。

主要发现

  • 135例疑似岛叶癫痫患者植入共303根岛叶电极(每例1-6根),共562个触点。
  • 268根电极(88.5%)经额顶或颞岛盖正交植入(420个触点);35根电极(11.5%)经额或顶入路斜向植入(142个触点)。
  • 19例(14.07%)患者双侧植入岛叶电极。
  • 23例(占岛叶植入组的17.04%,占整个SEEG队列的11.6%)经SEEG确认发作起始区位于岛叶。
  • 无患者发生与岛叶电极相关的脑出血。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE Insular epilepsy is relatively rare; however, exploring the insular cortex when preoperative workup raises the suspicion of insular epilepsy is of paramount importance for accurate localization of the epileptogenic zone and achievement of seizure freedom. The authors review their clinical experience with stereoelectroencephalography (SEEG) electrode implantation in patients with medically intractable epilepsy and suspected insular involvement. METHODS A total of 198 consecutive cases in which patients underwent SEEG implantation with a total of 1556 electrodes between June 2009 and April 2013 were reviewed. The authors identified patients with suspected insular involvement based on seizure semiology, scalp EEG data, and preoperative imaging (MRI, PET, and SPECT or magnetoencephalography [MEG]). Patients with at least 1 insular electrode based on the postoperative 3D reconstruction of CT fused with the preoperative MRI were included. RESULTS One hundred thirty-five patients with suspected insular epilepsy underwent insular implantation of a total of 303 electrodes (1-6 insular electrodes per patient) with a total of 562 contacts. Two hundred sixty-eight electrodes (88.5%) were implanted orthogonally through the frontoparietal or temporal operculum (420 contacts). Thirty-five electrodes (11.5%) were implanted by means of an oblique trajectory either through a frontal or a parietal entry point (142 contacts). Nineteen patients (14.07%) had insular electrodes placed bilaterally. Twenty-three patients (17.04% of the insular implantation group and 11.6% of the whole SEEG cohort) were confirmed by SEEG to have ictal onset zones in the insula. None of the patients experienced any intracerebral hemorrhage related to the insular electrodes. After insular resection, 5 patients (33.3%) had Engel Class I outcomes, 6 patients (40%) had Engel Class II, 3 patients (20%) had Engel Class III, and 1 patient (6.66%) had Engel Class IV. CONCLUSIONS Insula exploration with stereotactically placed depth electrodes is a safe technique. Orthogonal electrodes are implanted when the hypothesis suggests opercular involvement; however, oblique electrodes allow a higher insular sampling rate.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Alomar S, Mullin JP, Smithason S, et al. Indications, technique, and safety profile of insular stereoelectroencephalography electrode implantation in medically intractable epilepsy. J Neurosurg. 2017. PMID: 28621621. doi:10.3171/2017.1.JNS161070

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。