前路经胸手术治疗高危胸椎间盘突出症并运动诱发电位监测:技术与结果
本文报告采用运动诱发电位监测(MEPm)行前路经胸手术治疗高危胸椎间盘突出症(TDH)的经验。在435例前路经胸手术中,77例为高危TDH,分析其临床与影像学特征及MEP信号变化。最大TDH前后径、椎管占位率、脊髓受压率、(次)完全钙化及髓内信号改变与下肢MEP信号恶化相关;在有经验的术者手中,TMD联合MEPm支持对高危TDH是安全、高效的手术。
要点
- 最大TDH前后径、椎管占位率、脊髓受压率、(次)完全钙化及髓内信号改变与下肢MEP信号恶化相关。
- MEP信号恶化>50%判定为显著;术中灵敏度100%、特异度75%、阳性预测值19%,术毕阳性预测值44%。
- 在有经验的术者手中,TMD联合MEPm支持对高危TDH是安全、高效的手术。
核心结论
- 最大TDH前后径、椎管占位率、脊髓受压率、(次)完全钙化及髓内信号改变与下肢MEP信号恶化相关。
- 在有经验的术者手中,TMD联合MEPm支持对高危TDH是安全、高效的手术。
研究设计与样本
- 单中心回顾性分析435例前路经胸手术,其中77例为高危TDH(69例单节段,8例多节段;61例临床脊髓病,6例仅有髓内信号改变)。
- 根据临床和影像学特征评估手术风险,包括前后位椎管占位率(SCO)、前后位脊髓受压率(SCC)、残余前后位脊髓直径(RSCD)及髓内信号改变(ISC)。
- 分析Anand、ASIA和Nurick评分及麻醉、神经生理和手术记录;MEP信号恶化>50%视为显著。
主要发现
- 单节段病例平均SCO和SCC分别为55.4%和54.0%,多节段病例分别为31.8%和33.9%。
- 单节段病例ISC存在64%、钙化87%;多节段病例ISC存在50%、钙化84%。
- 最初行23例微型经胸入路(mini-TTA)和24例胸腔镜显微椎间盘切除术(TMD),近期行29例TMD(其中23例巨大TDH)和1例经腋下mini-TTA。
- 72例患者MEP信号可靠;孤立下肢MEP信号恶化(n=21)与最大TDH前后径、SCO、SCC及ISC相关。
- ASIA和Nurick评分分别改善45%和66%;1例患者截瘫。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To present our experience with anterior transthoracic surgery for high-risk thoracic disc herniations (TDHs) using motor evoked potential monitoring (MEPm). METHODS: We estimated surgical risk based on clinical and radiologic characteristics, including anteroposterior (AP) spinal canal occupation (SCO), AP spinal cord compression (SCC), residual AP spinal cord diameter (RSCD), and intramedullary signal changes (ISC). We analyzed Anand, ASIA, and Nurick scores, anesthesiologic, neurophysiological, and surgical reports. We considered >50% MEP signal deterioration significant. RESULTS: Out of 435 anterior transthoracic procedures, 77 concerned high-risk TDH(s): 69 single-level, 8 multilevel, 61 with clinical myelopathy, 6 with merely ISC. Mean SCO and SCC were 55.4% and 54.0% for single-level, 31.8% and 33.9% for multilevel cases. ISC were present in 64% of single-level and 50% of multilevel cases, calcifications in 87% of single-level and 84% of multilevel TDHs. We initially performed 23 mini-transthoracic approaches (mini-TTAs) and 24 thoracoscopic microdiscectomies (TMDs), more recently 29 TMDs (23 giant TDHs) and 1 transaxillary mini-TTA. Overall, 72 patients had reliable MEP signals. Isolated lower extremity MEP signal deteriorations (n = 21) correlated with maximal TDH AP diameter, SCO, SCC, and ISC. ASIA and Nurick scores improved in 45% and 66% respectively. One patient became paraplegic. MEP signal deterioration had 100% sensitivity, 75% specificity, and 19% positive predictive value during and 44% at the end of surgery. CONCLUSIONS: Maximal TDH AP diameter, SCO, SCC, (sub)total calcification, and ISC correlate with lower extremity MEP signal deterioration. In experienced hands, TMD with MEPm support is a safe, efficient procedure for high-risk TDHs.
引用
- Cornips E, Habets J, van Kranen-Mastenbroek V, et al. Anterior Transthoracic Surgery with Motor Evoked Potential Monitoring for High-Risk Thoracic Disc Herniations: Technique and Results. World Neurosurg. 2017. PMID: 28599909. doi:10.1016/j.wneu.2017.05.173
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。