双平面透视引导下经皮脊髓刺激电极植入:技术要点

Biplanar Fluoroscopy-Guided Percutaneous Lead Implantation for Spinal Cord Stimulation: Technical Note.
PubMed 文献 · World Neurosurg · 2017-06-20

该回顾性研究纳入2006至2011年间经皮植入脊髓刺激(SCS)电极用于试验性神经刺激的94例患者(72例胸腰段、22例颈段),其中73例使用2台C臂、21例使用单台C臂。颈段与胸腰段组中双平面配置均与手术阶段平均时长缩短相关(分别缩短29分钟,P=0.017;14分钟,P=0.016),但术前准备阶段延长;两组在手术室总时长与总辐射暴露时间上无显著差异。

要点

  • 颈段双平面配置与手术阶段平均缩短29分钟相关(P=0.017)。
  • 胸腰段双平面配置与手术阶段平均缩短14分钟相关(P=0.016)。
  • 双平面配置未增加总辐射暴露时间,但延长了术前准备阶段。

核心结论

  • 双平面透视配置与SCS电极植入手术时长缩短相关,且未增加总辐射暴露,作者认为这是对当前实践的一种实用且安全的调整。

研究设计与样本

  • 回顾性研究,纳入2006至2011年间经皮植入SCS电极用于试验性神经刺激的病例,共94例(72例胸腰段、22例颈段),其中73例使用2台C臂、21例使用单台C臂。

主要发现

  • 颈段组双平面配置与手术阶段平均时长缩短29分钟相关(P=0.017),胸腰段组缩短14分钟(P=0.016),但术前准备阶段时长增加。
  • 双平面配置组与单C臂组在手术室总时长及总辐射暴露时间上无显著差异。

临床怎么用

  • 作者认为双平面透视配置是当前实践的一种实用且安全的调整。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The correct positioning of spinal cord stimulator leads is assessed radiographically during their percutaneous implantation for trial stimulation. Usually the C-arm is repositioned several times to allow imaging in different planes, which may extend the total duration of surgery. The study aimed to evaluate whether the concurrent intraoperative use of 2 C-arms could safely reduce the duration of surgery. MATERIALS: This retrospective study included cases of percutaneous implantation of a spinal cord stimulation (SCS) lead for trial neurostimulation between 2006 and 2011. The duration of the surgical intervention was recorded, along with the duration of the preparation stage in the operating room. In addition, total radiation exposure time per case was recorded. RESULTS: Ninety-four patients underwent percutaneous implantation of an SCS lead (72 thoracolumbar, 22 cervical). In 73 cases 2 C-arms were used, with 21 cases performed with a single C-arm. In both the cervical and thoracolumbar groups, a biplanar configuration was associated with significant reduction in the mean length of the surgical phase, by 29 minutes (P = 0.017) and 14 minutes, respectively (P = 0.016), albeit while increasing the duration of the preoperative preparation stage. There was no significant difference in the total duration in the operating room or in the total radiation exposure time between groups. CONCLUSIONS: Here we present a technical note on the use of a biplanar fluoroscopy configuration for percutaneous implantation of SCS leads. This arrangement correlated with a reduction in surgery duration without increasing total radiation exposure, representing a practical and safe adjustment to current practice.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Lawson McLean A, Frank S, Staribacher D, et al. Biplanar Fluoroscopy-Guided Percutaneous Lead Implantation for Spinal Cord Stimulation: Technical Note. World Neurosurg. 2017. PMID: 28645599. doi:10.1016/j.wneu.2017.06.086

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。