荧光素钠辅助引导非强化胶质瘤诊断性肿瘤组织采样
研究纳入13例非强化、T2/FLAIR高信号疑似胶质瘤患者,术中静脉给予荧光素钠(10%,3 mg/kg),评估荧光能否识别诊断性组织及区分高恶性潜能区域。10/13例(77%)在T2/FLAIR高信号区内见斑片状荧光,荧光区样本更可能显示诊断性胶质瘤组织和细胞异型性(P < .05),荧光对诊断性组织存在的阳性预测值为95%,荧光区样本总细胞密度和Ki-67标记高于非荧光活检(P < .05)。
要点
- 13例非强化胶质瘤中10例(77%)在T2/FLAIR高信号区内见斑片状荧光。
- 荧光区样本更可能显示诊断性胶质瘤组织和细胞异型性(P < .05)。
- 荧光对诊断性组织存在的阳性预测值为95%,荧光区细胞密度和Ki-67标记更高(P < .05)。
核心结论
- 非强化胶质瘤中的荧光高度预测诊断性肿瘤组织以及细胞密度更高和增殖活性更高的区域。
研究设计与样本
- 13例表现为非强化、T2/FLAIR高信号疑似胶质瘤的患者,在手术切除期间接受荧光素钠(10%,3 mg/kg静脉给药)。
主要发现
- 13例中有10例(77%)在T2/FLAIR高信号区内识别到斑片状荧光。
- 取自荧光区域的样本更可能显示诊断性胶质瘤组织和细胞异型性(P < .05)。
- 荧光素对诊断性组织存在的阳性预测值为95%。
- 荧光区域样本的总细胞密度和Ki-67标记高于非荧光活检(P < .05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Accurate tissue sampling in nonenhancing (NE) gliomas is a unique surgical challenge due to their intratumoral histological heterogeneity and absence of contrast enhancement as a guide for intraoperative stereotactic guidance. Instead, T2/fluid-attenuated inversion-recovery (FLAIR) hyperintensity on MRI is commonly used as an imaging surrogate for pathological tissue, but sampling from this region can yield nondiagnostic or underdiagnostic brain tissue. Sodium fluorescein is an intraoperative fluorescent dye that has a high predictive value for tumor identification in areas of contrast enhancement and NE in glioblastomas. However, the underlying histopathological alterations in fluorescent regions of NE gliomas remain undefined. OBJECTIVE: To evaluate whether fluorescein can identify diagnostic tissue and differentiate regions with higher malignant potential during surgery for NE gliomas, thus improving sampling accuracy. METHODS: Thirteen patients who presented with NE, T2/FLAIR hyperintense lesions suspicious for glioma received fluorescein (10%, 3 mg/kg intravenously) during surgical resection. RESULTS: Patchy fluorescence was identified within the T2/FLAIR hyperintense area in 10 of 13 (77%) patients. Samples taken from fluorescent regions were more likely to demonstrate diagnostic glioma tissue and cytologic atypia (P < .05). Fluorescein demonstrated a 95% positive predictive value for the presence of diagnostic tissue. Samples from areas of fluorescence also demonstrated greater total cell density and higher Ki-67 labeling than nonfluorescent biopsies (P < .05). CONCLUSION: Fluorescence in NE gliomas is highly predictive of diagnostic tumor tissue and regions of higher cell density and proliferative activity.
引用
- Bowden SG, Neira JA, Gill BJA, et al. Sodium Fluorescein Facilitates Guided Sampling of Diagnostic Tumor Tissue in Nonenhancing Gliomas. Neurosurgery. 2018. PMID: 28645214. doi:10.1093/neuros/nyx271
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。