颅内压升高时观看短片可检测到可逆的眼动追踪改变

Elevated intracranial pressure and reversible eye-tracking changes detected while viewing a film clip.
PubMed 文献 · J Neurosurg · 2017-06-02

本研究对23例需放置颅内压监测的清醒患者进行55次眼动追踪,观看220秒短片,发现眼动追踪指标随颅内压升高呈线性下降,其中展神经功能指标受影响最明显;区分颅内压<12与≥12、<15与≥15、<20与≥20 mm Hg的曲线下面积分别为0.798、0.833、0.889。

要点

  • 眼动追踪指标随颅内压升高呈线性下降,展神经功能指标最明显。
  • 区分颅内压<12与≥12 mm Hg的曲线下面积为0.798。
  • 区分颅内压<15与≥15 mm Hg的曲线下面积为0.833。

核心结论

  • 颅内压升高与观看短片时眼动追踪异常加重相关。
  • 作者认为眼动追踪可能作为无创、可自动化的手段量化颅内压升高的生理影响。

研究设计与样本

  • 对需临床放置颅内压监测的清醒患者进行眼动追踪,观看220秒连续播放的短片。
  • 瞳孔位置以500 Hz记录,分别计算单眼和双眼的指标。
  • 采用广义估计方程线性回归检验眼动追踪指标与颅内压变化的关联。
  • 共23例患者(12女、11男,平均年龄46.8岁)在55次不同场合下完成眼动追踪,颅内压范围为-3至30 mm Hg。

主要发现

  • 与颅神经功能相关的眼动追踪指标随颅内压升高呈线性下降(p < 0.001)。
  • 展神经(CN VI)相关指标受影响最明显。
  • 区分颅内压<12与≥12 mm Hg的曲线下面积为0.798。
  • 区分颅内压<15与≥15 mm Hg的曲线下面积为0.833。
  • 区分颅内压<20与≥20 mm Hg的曲线下面积为0.889。

关键数值与推荐

  • 眼动追踪指标区分颅内压<12与≥12 mm Hg的曲线下面积为0.798。
  • 眼动追踪指标区分颅内压<15与≥15 mm Hg的曲线下面积为0.833。
  • 眼动追踪指标区分颅内压<20与≥20 mm Hg的曲线下面积为0.889。

临床怎么用

  • 作者认为眼动追踪可能作为无创、可自动化的手段量化颅内压升高的生理影响。
  • 作者提出其临床应用于评估分流管功能障碍、假性脑瘤、脑震荡和预防二次撞击综合征。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE The precise threshold differentiating normal and elevated intracranial pressure (ICP) is variable among individuals. In the context of several pathophysiological conditions, elevated ICP leads to abnormalities in global cerebral functioning and impacts the function of cranial nerves (CNs), either or both of which may contribute to ocular dysmotility. The purpose of this study was to assess the impact of elevated ICP on eye-tracking performed while patients were watching a short film clip. METHODS Awake patients requiring placement of an ICP monitor for clinical purposes underwent eye tracking while watching a 220-second continuously playing video moving around the perimeter of a viewing monitor. Pupil position was recorded at 500 Hz and metrics associated with each eye individually and both eyes together were calculated. Linear regression with generalized estimating equations was performed to test the association of eye-tracking metrics with changes in ICP. RESULTS Eye tracking was performed at ICP levels ranging from -3 to 30 mm Hg in 23 patients (12 women, 11 men, mean age 46.8 years) on 55 separate occasions. Eye-tracking measures correlating with CN function linearly decreased with increasing ICP (p < 0.001). Measures for CN VI were most prominently affected. The area under the curve (AUC) for eye-tracking metrics to discriminate between ICP < 12 and ≥ 12 mm Hg was 0.798. To discriminate an ICP < 15 from ≥ 15 mm Hg the AUC was 0.833, and to discriminate ICP < 20 from ≥ 20 mm Hg the AUC was 0.889. CONCLUSIONS Increasingly elevated ICP was associated with increasingly abnormal eye tracking detected while patients were watching a short film clip. These results suggest that eye tracking may be used as a noninvasive, automatable means to quantitate the physiological impact of elevated ICP, which has clinical application for assessment of shunt malfunction, pseudotumor cerebri, concussion, and prevention of second-impact syndrome.

来源:J Neurosurg,查看原文。版权归原作者所有。