早期低脑血流量与高脑乳酸:预测蛛网膜下腔出血后迟发性脑缺血
该研究纳入30例重型蛛网膜下腔出血患者,在发病后第0-3天用床旁氙-CT测量脑血流量(CBF),并用微透析检测间质葡萄糖、乳酸、丙酮酸、甘油和谷氨酸。30例中9例发生迟发性脑缺血(DCI);发生DCI的患者整体和区域CBF显著降低,乳酸显著升高,乳酸/丙酮酸比值也升高。作者认为早期低CBF及高乳酸、高乳酸/丙酮酸比值可能是发生DCI风险的早期预警信号,但需在更大规模研究中确认其临床价值。
要点
- 30例重型蛛网膜下腔出血患者中9例发生迟发性脑缺血。
- 发生DCI者整体和区域脑血流量显著降低,乳酸显著升高。
- 发生DCI者乳酸/丙酮酸比值也升高。
核心结论
- 早期低脑血流量测量值以及高乳酸和高乳酸/丙酮酸比值可能是发生迟发性脑缺血风险的早期预警信号。
- 这些发现的临床价值需在更大规模研究中确认。
研究设计与样本
- 研究纳入30例重型蛛网膜下腔出血患者。
- 在发病后第0-3天使用床旁氙-CT测量脑血流量。
- 使用微透析测量间质葡萄糖、乳酸、丙酮酸、甘油和谷氨酸。
主要发现
- 30例患者中9例发生迟发性脑缺血。
- 发生DCI的患者整体和区域脑血流量显著降低。
- 发生DCI的患者乳酸显著升高。
- 发生DCI的患者乳酸/丙酮酸比值升高。
临床怎么用
- 原文未据此给出推荐。
局限性
- 这些发现的临床价值需在更大规模研究中确认。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE Delayed cerebral ischemia (DCI) following subarachnoid hemorrhage (SAH) is one of the major contributors to poor outcome. It is crucial to be able to detect early signs of DCI to prevent its occurrence. The objective of this study was to determine if low cerebral blood flow (CBF) measurements and pathological microdialysis parameters measured at the bedside can be observed early in patients with SAH who later developed DCI. METHODS The authors included 30 patients with severe SAH. The CBF measurements were performed at Day 0-3 after disease onset, using bedside xenon-CT. Interstitial glucose, lactate, pyruvate, glycerol, and glutamate were measured using microdialysis. RESULTS Nine of 30 patients developed DCI. Patients with DCI showed significantly lower global and regional CBF, and lactate was significantly increased in these patients. A high lactate/pyruvate ratio was also detected in patients with DCI. CONCLUSIONS Early low CBF measurements and a high lactate and lactate/pyruvate ratio may be early warning signs of the risk of developing DCI. The clinical value of these findings needs to be confirmed in larger studies.
引用
- Rostami E, Engquist H, Howells T, et al. Early low cerebral blood flow and high cerebral lactate: prediction of delayed cerebral ischemia in subarachnoid hemorrhage. J Neurosurg. 2017. PMID: 28574309. doi:10.3171/2016.11.JNS161140
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。