ABC/2法不能准确预测脑动静脉畸形体积
本研究回顾性分析1995至2015年接受立体定向放射外科(SRS)治疗的90例颅内动静脉畸形(AVM),比较基于数字减影血管造影(DSA)的ABC/2公式与SRS计划软件计算的病灶体积。结果显示ABC/2法高估AVM体积,且对大于7 cm³的AVM高估更明显,两者相关性中等(r=0.662)。
要点
- ABC/2法高估脑AVM体积,与SRS计划体积差异显著(P=.002)。
- AVM大于7 cm³时,ABC/2法高估程度更大(P<.001)。
- ABC/2法与SRS计划体积仅呈中等相关(r=0.662)。
核心结论
- ABC/2法较SRS计划软件体积分析高估脑AVM体积。
- 对于大于7 cm³的AVM,高估程度更大。
- SRS计划技术与圆锥和圆柱公式推导值亦存在显著差异。
研究设计与样本
- 回顾性检索神经血管数据库,纳入1995至2015年接受SRS治疗的颅内AVM。
- 记录DSA图像正交平面上最大病灶直径,用ABC/2公式计算体积。
- 从SRS手术记录中提取病灶靶体积,采用描述性统计和配对t检验比较。
主要发现
- 共识别90例颅内AVM。
- SRS计划法中位体积为4.96 cm³(IQR 1.79-8.85),ABC/2法中位体积为6.07 cm³(IQR 1.3-13.6)。
- SRS与ABC/2之间呈中等相关(r=0.662;P<.001)。
- 配对样本t检验显示SRS体积与ABC/2体积差异显著(t=-3.2;P=.002)。
- 按ABC/2体积二分后差异仍显著:ABC/2体积<7 cm³组t=3.1,P=.003;ABC/2体积>7 cm³组t=-4.4,P<.001。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Stereotactic radiosurgery (SRS) is a treatment option for cerebral arteriovenous malformations (AVMs) to prevent intracranial hemorrhage. The decision to proceed with SRS is usually based on calculated nidal volume. Physicians commonly use the ABC/2 formula, based on digital subtraction angiography (DSA), when counseling patients for SRS. OBJECTIVE: To determine whether AVM volume calculated using the ABC/2 method on DSA is accurate when compared to the exact volume calculated from thin-cut axial sections used for SRS planning. METHODS: Retrospective search of neurovascular database to identify AVMs treated with SRS from 1995 to 2015. Maximum nidal diameters in orthogonal planes on DSA images were recorded to determine volume using ABC/2 formula. Nidal target volume was extracted from operative reports of SRS. Volumes were then compared using descriptive statistics and paired t-tests. RESULTS: Ninety intracranial AVMs were identified. Median volume was 4.96 cm3 [interquartile range (IQR) 1.79-8.85] with SRS planning methods and 6.07 cm3 (IQR 1.3-13.6) with ABC/2 methodology. Moderate correlation was seen between SRS and ABC/2 (r = 0.662; P < .001). Paired sample t-tests revealed significant differences between SRS volume and ABC/2 (t = -3.2; P = .002). When AVMs were dichotomized based on ABC/2 volume, significant differences remained (t = 3.1, P = .003 for ABC/2 volume < 7 cm3; t = -4.4, P < .001 for ABC/2 volume > 7 cm3). CONCLUSION: The ABC/2 method overestimates cerebral AVM volume when compared to volumetric analysis from SRS planning software. For AVMs > 7 cm3, the overestimation is even greater. SRS planning techniques were also significantly different than values derived from equations for cones and cylinders.
引用
- Roark C, Vadlamudi V, Chaudhary N, et al. ABC/2 Method Does not Accurately Predict Cerebral Arteriovenous Malformation Volume. Neurosurgery. 2018. PMID: 28605551. doi:10.1093/neuros/nyx139
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。