使用带电超声吸引器在髓内脊髓肿瘤手术中对皮质脊髓束进行连续定位
该研究回顾性分析了6例髓内脊髓肿瘤患者,在经典经颅电刺激运动诱发电位(tcMEP)和D波监测基础上,使用超声吸引器尖端进行运动纤维连续邻近定位。作者初步认为该技术融合可能有助于优化切除并保留神经功能。
要点
- 髓内脊髓肿瘤占中枢神经系统肿瘤的4%-10%,显微手术切除是主要治疗方式。
- 经典监测方法存在损伤与信号揭示之间的固有延迟,且tcMEP常因患者制动需求受限。
- 作者初步经验显示超声吸引器尖端连续定位可与经典监测联合用于运动纤维定位。
核心结论
- 作者初步认为,超声吸引器尖端连续邻近定位与经典肌电tcMEP及D波监测融合,可能有助于在髓内脊髓肿瘤手术中优化切除并保留神经功能。
研究设计与样本
- 回顾性系列综述,纳入6例接受髓内脊髓肿瘤切除的患者,使用超声吸引器尖端进行脊髓内运动纤维连续邻近定位,并联合经典肌电tcMEP和D波监测。
主要发现
- 髓内脊髓肿瘤占所有中枢神经系统肿瘤的4%-10%。
- 经典监测技术下,皮质脊髓束实际结构或血管性损伤与其信号揭示之间可能存在固有延迟。
- tcMEP刺激常因术者希望患者不抽动而受限,尤其在切除最关键时段。
- D波监测可能需要数秒平均才能更新,且对侧别有一定的不区分性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Intramedullary spinal cord tumors (IMSCTs) represent a rare entity, accounting for 4%-10% of all central nervous system tumors. Microsurgical resection of IMSCTs is currently considered the primary treatment modality. Intraoperative neurophysiological monitoring (IONM) has been shown to aid in maximizing tumor resection and minimizing neurological morbidity, consequently improving patient outcome. The gold standard for IONM to date is multimodality monitoring, consisting of both somatosensory evoked potentials, as well as muscle-based transcranial electric motor evoked potentials (tcMEPs). Monitoring of tcMEPs is optimal when combining transcranial electrically stimulated muscle tcMEPs with D-wave monitoring. Despite continuous monitoring of these modalities, when classic monitoring techniques are used, there can be an inherent delay in time between actual structural or vascular-based injury to the corticospinal tracts (CSTs) and its revelation. Often, tcMEP stimulation is precluded by the surgeon's preference that the patient not twitch, especially at the most crucial times during resection. In addition, D-wave monitoring may require a few seconds of averaging until updating, and can be somewhat indiscriminate to laterality. Therefore, a method that will provide immediate information regarding the vulnerability of the CSTs is still needed. The authors performed a retrospective series review of resection of IMSCTs using the tip of an ultrasonic aspirator for continuous proximity mapping of the motor fibers within the spinal cord, along with classic muscle-based tcMEP and D-wave monitoring. The authors present their preliminary experience with 6 patients who underwent resection of an IMSCT using the tip of an ultrasonic aspirator for continuous proximity mapping of the motor fibers within the spinal cord, together with classic muscle-based tcMEP and D-wave monitoring. This fusion of technologies can potentially assist in optimizing resection while preserving neurological function in these challenging surgeries.
引用
- Barzilai O, Lidar Z, Constantini S, et al. Continuous mapping of the corticospinal tracts in intramedullary spinal cord tumor surgery using an electrified ultrasonic aspirator. J Neurosurg Spine. 2017. PMID: 28524753. doi:10.3171/2016.12.SPINE16985
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。