使用共聚焦反射显微镜对垂体腺瘤进行离体即刻诊断:一项原理验证研究
本研究评估离体共聚焦反射显微镜(CRM)在手术活检标本中区分垂体腺瘤与正常垂体的可行性。11例疑似垂体腺瘤患者的标本立即行CRM成像并与H&E染色对照,盲法阅片在16张图像中15张(94%)确认诊断。CRM可快速、无标记评估标本,并保留组织用于后续永久分析。
要点
- CRM可快速、无标记评估垂体活检标本,保留组织用于永久分析。
- 盲法神经病理学家在16张图像中15张(94%)正确区分腺瘤与正常腺体。
- CRM图像中腺瘤呈片状和大叶状细胞,正常组织呈散在小叶状上皮细胞。
核心结论
- CRM是一种简单、可靠的方法,可在离体快速评估垂体腺瘤标本。
- 该技术能准确区分垂体腺瘤与正常腺体,同时保留活检组织用于未来永久分析、免疫组化及分子研究。
研究设计与样本
- 研究纳入11例疑似垂体腺瘤患者的活检标本,标本直接送至病理科。
- 标本立即定位并使用位于冰冻切片制备区的共聚焦显微镜行CRM成像,随后制备H&E染色切片。
- 一名神经病理学家比较H&E与匹配CRM图像的组织病理学特征,另一名神经病理学家以盲法阅片并诊断腺瘤或正常腺体。
主要发现
- 所有标本的CRM均能对比细胞密度、组织结构、核多形性、血管分布和间质。
- 垂体腺瘤在CRM中显示片状和大叶状细胞,与匹配的H&E染色切片相似。
- 正常组织的CRM图像显示散在的小叶状垂体上皮细胞,与匹配的正常腺体H&E图像一致。
- 盲法阅片在16张腺瘤与正常腺体图像中确认诊断15张(94%)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE The objective of this study was to evaluate the feasibility of using confocal reflectance microscopy (CRM) ex vivo to differentiate adenoma from normal pituitary gland in surgical biopsy specimens. CRM allows for rapid, label-free evaluation of biopsy specimens with cellular resolution while avoiding some limitations of frozen section analysis. METHODS Biopsy specimens from 11 patients with suspected pituitary adenomas were transported directly to the pathology department. Samples were immediately positioned and visualized with CRM using a confocal microscope located in the same area of the pathology department where frozen sections are prepared. An H & E-stained slide was subsequently prepared from imaged tissue. A neuropathologist compared the histopathological characteristics of the H & E-stained slide and the matched CRM images. A second neuropathologist reviewed images in a blinded fashion and assigned diagnoses of adenoma or normal gland. RESULTS For all specimens, CRM contrasted cellularity, tissue architecture, nuclear pleomorphism, vascularity, and stroma. Pituitary adenomas demonstrated sheets and large lobules of cells, similar to the matched H & E-stained slides. CRM images of normal tissue showed scattered small lobules of pituitary epithelial cells, consistent with matched H & E-stained images of normal gland. Blinded review by a neuropathologist confirmed the diagnosis in 15 (94%) of 16 images of adenoma versus normal gland. CONCLUSIONS CRM is a simple, reliable approach for rapidly evaluating pituitary adenoma specimens ex vivo. This technique can be used to accurately differentiate between pituitary adenoma and normal gland while preserving biopsy tissue for future permanent analysis, immunohistochemical studies, and molecular studies.
引用
- Mooney MA, Georges J, Yazdanabadi MI, et al. Immediate ex-vivo diagnosis of pituitary adenomas using confocal reflectance microscopy: a proof-of-principle study. J Neurosurg. 2017. PMID: 28548594. doi:10.3171/2016.11.JNS161651