颅内压监测常可推翻特发性颅内高压的诊断
本研究通过账单记录回顾性纳入3年内30例特发性颅内高压(IIH)患者,在分流术或翻修术前进行颅内压(ICP)监测。此前6个月内17例腰椎穿刺均示开放压力升高,但直接ICP监测仅2例(12%)持续升高;15例评估分流者中4例(27%)ICP升高,15例已有分流者中2例(13%)分流管功能异常、3例(20%)分流管不必要而移除。结论认为直接ICP监测是确定ICP的金标准,可安全有效地用于IIH诊疗以减少误诊和不必要手术。
要点
- 17例腰穿开放压力升高者中仅2例(12%)直接ICP监测持续升高。
- 15例评估分流者中4例(27%)直接ICP监测发现ICP升高。
- 15例已有分流者中3例(20%)分流管被认定不必要并移除。
核心结论
- 直接ICP监测是确定ICP的金标准,可安全有效地用于IIH的检查与治疗,以减少误诊和不必要手术。
研究设计与样本
- 通过账单记录回顾性识别3年期间诊断为IIH并在分流术或翻修术前接受ICP监测的所有患者,共30例,采用脑实质内导线监测。
主要发现
- 30例中17例在此前6个月内接受腰椎穿刺,开放压力均升高,但直接ICP监测仅2例(12%)持续ICP升高。
- 15例评估分流者中4例(27%)直接ICP监测发现ICP升高。
- 15例已有分流者中2例(13%)压力监测后发现分流管功能异常,3例(20%)分流管被认定不必要并移除。
- 侵入性监测未发生任何并发症。
临床怎么用
- 作者认为直接ICP监测是确定ICP的金标准,可安全有效地应用于IIH的检查与治疗,以减少误诊和不必要手术。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The diagnosis and management of patients with idiopathic intracranial hypertension (IIH) frequently relies on lumbar puncture to ascertain intracranial pressure (ICP). However, ICP values derived this way may be spurious owing to patient body habitus and behavior. We recently incorporated direct continuous ICP monitoring into the work-up for IIH. METHODS: Through billing records, we identified all patients during a 3-year period who had a diagnosis of IIH and who underwent ICP monitoring before shunt placement or revision. Patient demographics and clinical data were reviewed. RESULTS: Of 30 patients who underwent ICP monitoring with an intraparenchymal wire, 17 had undergone lumbar puncture within the previous 6 months. Results from lumbar punctures showed an elevated opening pressure in all 17 patients, whereas only 2 patients (12%) were found to have consistently elevated ICP with direct ICP monitoring. Of 15 patients being evaluated for shunting, 4 (27%) were found to have elevated ICP. Of the 15 patients with existing shunts, 2 patients (13%) were found to have malfunctioning shunts after pressure monitoring, and 3 patients (20%) had shunts that were found to be unnecessary and were removed. No patient experienced any complication from invasive monitoring. CONCLUSIONS: Direct ICP monitoring is the gold standard for determining ICP and can be safely and effectively applied to the work-up and treatment of patients with IIH to reduce the occurrence of misdiagnosis and unnecessary surgery.
引用
- Xu DS, Hlubek RJ, Mulholland CB, et al. Use of Intracranial Pressure Monitoring Frequently Refutes Diagnosis of Idiopathic Intracranial Hypertension. World Neurosurg. 2017. PMID: 28435117. doi:10.1016/j.wneu.2017.04.080
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。