文献速递功能神经外科

轨迹是否重要?丘脑底核脑深部电刺激中轨迹与靶点接合及误差容受关系的研究

Does trajectory matter? A study looking into the relationship of trajectory with target engagement and error accommodation in subthalamic nucleus deep brain stimulation.
PubMed 文献 · Acta Neurochir (Wien) · 2017-03-30

研究通过模拟电极轨迹评估丘脑底核脑深部电刺激中轨迹对接合与误差容受的影响。基于6例患者MRI重建12个丘脑底核,模拟56条轨迹并复评20条可行轨迹。结果显示特定角度轨迹可容纳超过2.4度偏移,半数轨迹平均接合达6毫米;作者建议首个试验轨迹取眉间前20度,并根据需要调整。

要点

  • 轨迹选择影响丘脑底核接合及对电极偏移或脑移位的容受能力。
  • 眉间前小于30度且偏离中线10至30度的轨迹可容纳超过2.4度偏移。
  • 作者建议首个试验轨迹取眉间前20度,后续向后外侧移动以平衡误差与接合。

核心结论

  • 轨迹选择影响接近选定丘脑底核靶点时的接合及对电极偏移或脑移位的容受能力。
  • 作者建议首个试验轨迹取眉间前20度,后续试验向后外侧移动以平衡误差与接合。
  • 当需要更宽误差范围时(如双侧手术的第二侧),建议采用靠近冠状缝且偏离中线约25度的轨迹。

研究设计与样本

  • 研究利用6例患者的磁共振成像数据三维重建12个丘脑底核,模拟经56条轨迹的电极放置并复评20条可行轨迹。
  • 另按上述方案收集14个丘脑底核的微电极轨迹数据。

主要发现

  • 眉间前小于30度且偏离中线10至30度的轨迹可容纳超过2.4度的偏移。
  • 20条可行轨迹的子集中,半数可实现平均6毫米的接合。
  • 最长接合出现在跨越冠状缝、向外侧延伸至40度的轨迹上。
  • 14个额外丘脑底核的微电极轨迹中,所有中央轨迹接合超过5毫米且无内囊侧效应。

临床怎么用

  • 作者建议首个试验轨迹取眉间前20度,后续试验向后外侧移动以平衡误差与接合。
  • 当需要更宽误差范围时(如双侧手术的第二侧),作者建议采用靠近冠状缝且偏离中线约25度的轨迹。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is now a key treatment choice for advanced Parkinson's disease. The optimum target area within the STN is well established. However, no emphasis on the impact of trajectory exists. The ellipsoid shape of the STN and the off-centre traditional target point mean that variation in the electrode inclination should affect STN engagement. Understanding of this relationship could inform trajectory selection during planning by improving STN engagements and margins for error. METHOD: We simulated electrode placement at the clinical target through a set of trial trajectories. Twelve three-dimensionally reconstructed STNs were created from magnetic resonance imaging data of six patients. An appropriate target within each STN was then chosen. Each STN was approached through 56 simulated trajectories arranged in a grid covering a quadrant of skull around and in front of the coronal suture. A subset of 20 viable trajectories was reassessed for depth of engagement in each STN whilst approaching the chosen target. RESULTS: Group averages for each trajectory are presented as traffic light maps and as an overlaid skull mask illustrating recommended electrode entry sites. Trajectories under 30 degrees anterior to the bregma and between 10 to 30 degrees off the midline accommodated over 2.4 degrees of wobble. A mean engagement of 6 mm was possible in half of the subset. The longest engagements are on trajectories which saddle the coronal suture, extending to 40 degrees lateral. Microelectrode tracts of 14 additional STNs were collated using the above protocol and engagement exceeded 5 mm in all central trajectories without capsular side effects, suggesting placement away from STN borders. CONCLUSIONS: Trajectory selection influences engagement and flexibility to accommodate electrode wobble or brain shift whilst approaching a chosen STN target. We recommend having the first trial trajectory 20 degrees anterior to the bregma, moving postero-laterally in successive trials to balance both error and engagement. When wider margins for error are beneficial (e.g. second side during bilateral procedures), trajectories nearer the coronal suture and around 25 degrees off the midline are advised.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Steel DA, Basu S. Does trajectory matter? A study looking into the relationship of trajectory with target engagement and error accommodation in subthalamic nucleus deep brain stimulation. Acta Neurochir (Wien). 2017. PMID: 28361249. doi:10.1007/s00701-017-3151-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。