苍白球电刺激治疗肌张力障碍中电极位置与临床结局的相关性

Correlation of electrode position and clinical outcomes in globus pallidus stimulation for dystonia.
PubMed 文献 · Acta Neurochir (Wien) · 2017-04-17

该回顾性研究纳入36例因肌张力障碍接受苍白球内侧部(GPi)脑深部电刺激(DBS)的患者,比较术后MRI实际电极位置与术前MRI理论靶点的差异,并分析电极位置与临床结局的相关性。结果显示所有电极坐标的理论值与实际值均有显著差异(p<0.05),Y坐标差异大于X和Z坐标;电极位于或靠近腹后侧GPi的患者临床结局更好。

要点

  • 36例肌张力障碍患者GPi DBS回顾性研究,比较理论靶点与实际电极位置。
  • 所有电极坐标理论值与实际值均有显著差异(p<0.05),Y坐标差异更大。
  • 电极位于或靠近腹后侧GPi的患者临床结局更好。

核心结论

  • 实际电极位置较理论规划靶点稍偏后,电极集中于腹后侧GPi附近倾向于获得良好结局。

研究设计与样本

  • 回顾性研究,纳入36例因肌张力障碍接受GPi DBS的患者。

主要发现

  • 所有电极位置的理论坐标与实际坐标均有显著差异(p<0.05),Y坐标差异大于X和Z坐标。
  • 左侧与右侧电极在各坐标定位准确性上无显著差异。
  • 电极位于或靠近腹后侧GPi的患者临床结局更好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The correlation between the electrode location and the clinical outcome for internal globus pallidus (GPi) deep brain stimulation (DBS) has not been fully elucidated. OBJECTIVE: The aim of this study was to determine the discrepancies between the theoretical target planned by magnetic resonance imaging (MRI) and the actual electrode location in postoperative MRI, as well as to find the correlation between the final electrode locations and the clinical outcome after GPi DBS. METHODS: Thirty-six patients who underwent GPi DBS for dystonia were included in this retrospective study. The X coordinate was defined as the lateral distance from the midline, the Y coordinate as the anterior distance from the midcommissural point, and the Z coordinate as the inferior distance from the intercommissural line. RESULTS: All coordinates showed a significant difference between theoretical and actual values for all electrode locations (p < 0.05). In particular, greater differences were exhibited for Y than for the X and Z coordinates. There was no significant difference in the accuracy of the localization of the left-side versus the right-side electrode for any coordinates. The patients whose electrodes were located within or near the posteroventral GPi showed better clinical outcomes. CONCLUSIONS: The actual electrode location was slightly more posterior to the theoretically planned target. Electrodes concentrated near the posteroventral GPi tended to yield favorable outcomes.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Park HR, Lee JM, Ehm G, et al. Correlation of electrode position and clinical outcomes in globus pallidus stimulation for dystonia. Acta Neurochir (Wien). 2017. PMID: 28413841. doi:10.1007/s00701-017-3182-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。