文献速递功能神经外科

低强度聚焦超声无创神经调控与丘脑定位

Noninvasive neuromodulation and thalamic mapping with low-intensity focused ultrasound.
PubMed 文献 · J Neurosurg · 2017-04-21

本研究在10只约克夏猪中验证低强度聚焦超声(LIFU)对丘脑的神经调控与选择性定位能力。LIFU靶向腹后外侧丘脑核使体感诱发电位(SSEP)波幅抑制至基线的71.6%±11.4%,空间分辨率约2 mm,可选择性抑制相邻丘脑核团;MR热成像未见组织升温,组织学未见损伤。结果提示LIFU可安全调控中枢神经系统神经环路,无创聚焦超声脑功能定位在人类中可能可行。

要点

  • LIFU靶向腹后外侧丘脑核使SSEP波幅抑制至基线的71.6%±11.4%。
  • LIFU空间分辨率约2 mm,可选择性抑制相邻丘脑核团而不影响邻近核团。
  • MR热成像未见组织升温,组织学未见组织损伤。

核心结论

  • 结果提示LIFU可安全用于调控中枢神经系统神经环路,无创聚焦超声脑功能定位在人类中可能可行。

研究设计与样本

  • 研究使用10只约克夏猪(Sus scrofa domesticus)。
  • 第一项神经调控实验将LIFU立体定向靶向丘脑 lemniscal 感觉丘脑并监测体感诱发电位(SSEP)。
  • 第二项定位实验交替靶向腹内侧与腹后外侧感觉丘脑核,同时记录三叉神经与胫神经诱发的SSEP。
  • 使用MR热成像评估声学焦点处温度,实验结束时对所有组织进行组织学损伤评估。

主要发现

  • LIFU靶向腹后外侧丘脑核使SSEP波幅抑制至基线的71.6%±11.4%(均值±标准差)。
  • LIFU以约2 mm的高空间分辨率实现相似程度的抑制,相邻丘脑核团可被选择性抑制。
  • 腹内侧丘脑核可被抑制而不影响腹外侧核。
  • MR热成像显示LIFU发射期间未见组织升温,组织学未见组织损伤证据。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE Ultrasound can be precisely focused through the intact human skull to target deep regions of the brain for stereotactic ablations. Acoustic energy at much lower intensities is capable of both exciting and inhibiting neural tissues without causing tissue heating or damage. The objective of this study was to demonstrate the effects of low-intensity focused ultrasound (LIFU) for neuromodulation and selective mapping in the thalamus of a large-brain animal. METHODS Ten Yorkshire swine ( Sus scrofa domesticus) were used in this study. In the first neuromodulation experiment, the lemniscal sensory thalamus was stereotactically targeted with LIFU, and somatosensory evoked potentials (SSEPs) were monitored. In a second mapping experiment, the ventromedial and ventroposterolateral sensory thalamic nuclei were alternately targeted with LIFU, while both trigeminal and tibial evoked SSEPs were recorded. Temperature at the acoustic focus was assessed using MR thermography. At the end of the experiments, all tissues were assessed histologically for damage. RESULTS LIFU targeted to the ventroposterolateral thalamic nucleus suppressed SSEP amplitude to 71.6% ± 11.4% (mean ± SD) compared with baseline recordings. Second, we found a similar degree of inhibition with a high spatial resolution (∼ 2 mm) since adjacent thalamic nuclei could be selectively inhibited. The ventromedial thalamic nucleus could be inhibited without affecting the ventrolateral nucleus. During MR thermography imaging, there was no observed tissue heating during LIFU sonications and no histological evidence of tissue damage. CONCLUSIONS These results suggest that LIFU can be safely used to modulate neuronal circuits in the central nervous system and that noninvasive brain mapping with focused ultrasound may be feasible in humans.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Dallapiazza RF, Timbie KF, Holmberg S, et al. Noninvasive neuromodulation and thalamic mapping with low-intensity focused ultrasound. J Neurosurg. 2017. PMID: 28430035. doi:10.3171/2016.11.JNS16976

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。