术中计算机断层扫描优化脑深部电刺激手术中的微电极记录
该研究比较了39例未使用术中计算机断层扫描外推法(iCTE)和使用iCTE的33例帕金森病患者接受丘脑底核脑深部电刺激(STN DBS)手术的情况。结果显示iCTE降低了微电极记录轨迹的径向误差、减少了手术时间和轨迹数,并增加了记录的STN长度。作者结论认为iCTE提高了微电极精度和STN首过记录长度,同时减少手术时间,但需进一步研究确定是否降低并发症和改善临床结局。
要点
- iCTE将微电极记录轨迹平均径向误差从1.90 ± 0.12 mm降至0.84 ± 0.09 mm(P < 0.001)。
- iCTE将双侧电极植入手术时间从272 ± 9分钟降至233 ± 10分钟(P < 0.001)。
- iCTE将每半球平均MER轨迹数从2.24 ± 0.13降至1.75 ± 0.09(P < 0.001),单轨迹定位比例从29%升至43%。
核心结论
- iCTE提高了微电极精度并增加了STN首过记录长度,同时减少了手术时间。
- 需进一步研究确定该技术是否减少并发症和改善临床结局。
研究设计与样本
- 回顾性比较研究:39例未使用iCTE的帕金森病STN DBS患者与33例使用iCTE的STN DBS患者进行比较。
- iCTE技术:硬脑膜打开前插入引导管并置于硬脑膜上,行术中CT,沿引导管创建轨迹并外推至目标,必要时调整头架,然后插入引导管行微电极记录。
主要发现
- iCTE组平均径向MER轨迹误差为0.84 ± 0.09 mm(n = 49),低于未使用iCTE组的1.90 ± 0.12 mm(n = 54)(P < 0.001)。
- iCTE组双侧电极植入手术时间为233 ± 10分钟(n = 24),短于未使用iCTE组的272 ± 9分钟(n = 30)(P < 0.001)。
- iCTE组每半球平均MER轨迹数为1.75 ± 0.09(n = 63),低于未使用iCTE组的2.24 ± 0.13(n = 66)(P < 0.001)。
- iCTE组需要单条MER轨迹定位的半球百分比为43%(n = 63),高于未使用iCTE组的29%(n = 66)。
- iCTE组平均记录STN长度为4.75 ± 0.28 mm(n = 56),长于未使用iCTE组的4.01 ± 0.3 mm(n = 64)(P < 0.05)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Microelectrode recording (MER) is used to confirm targeting accuracy during deep brain stimulation (DBS) surgery. We describe a technique using intraoperative computed tomography (CT) extrapolation (iCTE) to predetermine and adjust the trajectory of the guide tube to improve microelectrode targeting accuracy. We hypothesized that this technique would decrease the number of MER tracks and operative time, while increasing the recorded length of the subthalamic nucleus (STN). METHODS: Thirty-nine patients with Parkinson's disease who underwent STN DBS before the iCTE method were compared with 33 patients undergoing STN DBS using iCTE. Before dural opening, a guide tube was inserted and rested on dura. Intraoperative computed tomography (iCT) was performed, and a trajectory was created along the guide tube and extrapolated to the target using targeting software. If necessary, headstage adjustments were made to correct for error. The guide tube was inserted, and MER was performed. iCT was performed with the microelectrode tip at the target. Coordinates were compared with planned/adjusted track coordinates. Radial error between the MER track and the planned/adjusted track was calculated. Cases before and after implementation of iCTE were compared to determine the impact of iCTE on operative time, number of MER tracks and recorded STN length. RESULTS: The use of iCTE reduced the average radial MER track error from 1.90 ± 0.12 mm (n = 54) to 0.84 ± 0.09 mm (n = 49) (P < 0.001) while reducing the operative time for bilateral lead placement from 272 ± 9 minutes (n = 30) to 233 ± 10 minutes (n = 24) (P < 0.001). The average MER tracks per hemisphere was reduced from 2.24 ± 0.13 mm (n = 66) to 1.75 ± 0.09 mm (n = 63) (P < 0.001), whereas the percentage of hemispheres requiring a single MER track for localization increased from 29% (n = 66) to 43% (n = 63). The average length of recorded STN increased from 4.01 ± 0.3 mm (n = 64) to 4.75 ± 0.28 mm (n = 56) (P < 0.05). CONCLUSION: iCTE improves microelectrode accuracy and increases the first-pass recorded length of STN, while reducing operative time. Further studies are needed to determine whether this technique leads to less morbidity and improved clinical outcomes.
引用
- Kochanski RB, Bus S, Pal G, et al. Optimization of Microelectrode Recording in Deep Brain Stimulation Surgery Using Intraoperative Computed Tomography. World Neurosurg. 2017. PMID: 28408262. doi:10.1016/j.wneu.2017.04.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。