高b值扩散加权3T磁共振成像对幕上非强化胶质瘤的术前分级
本研究纳入39例幕上非强化胶质瘤患者,行常规MRI及标准b值(1000 s/mm²)与高b值(3000 s/mm²)DWI,测量ADC最小值、最大值和平均值。高b值下非强化高级别与低级别胶质瘤的ADC值差异更大(均P<0.0001),高b值ADC平均值鉴别效能最佳,截断值0.814×10⁻³ mm²/s。
要点
- 高b值(3000 s/mm²)DWI测得的ADC值有助于幕上非强化胶质瘤的术前分级。
- 非强化高级别胶质瘤的ADC最小值、最大值和平均值均低于低级别胶质瘤。
- 高b值ADC平均值鉴别高低级别胶质瘤的截断值为0.814×10⁻³ mm²/s。
核心结论
- 高b值DWI获得的ADC值可用于非强化高级别与低级别胶质瘤的分级和手术管理。
- 以b值3000 s/mm²测得的ADC平均值重叠程度最低。
研究设计与样本
- 本研究纳入39例患者,行常规磁共振成像及标准b值(1000 s/mm²)和高b值(3000 s/mm²)扩散加权成像。
- 从两种b值的ADC图上测量ADC最小值、最大值和平均值,并采用受试者工作特征曲线分析确定鉴别非强化高级别与低级别胶质瘤的ADC截断值。
主要发现
- 非强化高级别胶质瘤的ADC最小值、最大值和平均值均低于低级别胶质瘤。
- 高b值时上述差异均P<0.0001,标准b值时分别为P=0.0001、P<0.0001和P<0.0001。
- 判别分析显示,以高b值测得的ADC平均值鉴别高级别与低级别胶质瘤的可能性最大,截断值为0.814×10⁻³ mm²/s。
- 以b值3000 s/mm²测定的ADC平均值重叠程度最低。
关键数值与推荐
- 高b值(3000 s/mm²)ADC平均值鉴别非强化高级别与低级别胶质瘤的截断值为0.814×10⁻³ mm²/s。
临床怎么用
- 原文结论认为高b值DWI获得的ADC值可用于非强化高级别与低级别胶质瘤的分级和手术管理。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The purpose of this study was to determine the difference in discrimination between high- and low-grade supratentorial nonenhancing gliomas (HGGs and LGGs, respectively) when using apparent diffusion coefficient (ADC) values with high or standard b-value. Thirty-nine patients underwent conventional magnetic resonance imaging and diffusion-weighted imaging (DWI) with standard and high b-values (b = 1000 and 3000 s/mm2, respectively). Minimum, maximum, and mean ADC values (ADCMIN, ADCMAX, and ADCMEAN, respectively) were measured from ADC maps with both b-values. Receiver operating curve analysis was used to determine the cutoff ADC values for distinguishing between nonenhancing HGGs and LGGs. ADCMIN, ADCMAX, and ADCMEAN values for the nonenhancing HGGs were lower than those for LGGs. These differences were much larger when a high b-value was used (all P < 0.0001) than when a standard b-value was used (P = 0.0001, <0.0001, and <0.0001, respectively). Discriminant analysis indicated that the greatest likelihood for discriminating HGGs and LGGs when ADCMEAN was obtained with a high b-value, with cutoff value of 0.814 × 10-3 mm2/s. ADC values obtained with a high b-value can be useful for grading and surgical management of nonenhancing HGGs and LGGs. The lowest degree of overlap was obtained when ADCMEAN was determined with a b-value of 3000 s/mm2.
引用
- Han H, Han C, Wu X, et al. Preoperative grading of supratentorial nonenhancing gliomas by high b-value diffusion-weighted 3 T magnetic resonance imaging. J Neurooncol. 2017. PMID: 28439776. doi:10.1007/s11060-017-2423-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。