137例在高场强术中磁共振导航下接受内镜下经蝶窦垂体腺瘤切除术患者的分析
该研究分析了137例在1.5T术中磁共振(iMRI)导航下接受内镜下经蝶窦垂体腺瘤切除术的患者,92例实时iMRI显示完全切除,45例有残留;23例进一步手术,其中19例达到全切除,总切除率从67.15%升至81.02%。结论认为iMRI和神经导航不仅提高肿瘤切除率,还有助于发现和清除术区血肿,术后3个月随访残留范围与术中结果一致。
要点
- 137例患者中,92例实时iMRI显示完全切除,45例有残留。
- 23例因残留行进一步手术,其中19例达到全切除。
- 总切除率从67.15%升至81.02%,iMRI发现3例术区出血并成功处理。
核心结论
- 使用iMRI和神经导航不仅提高肿瘤切除率,还有助于发现和清除术区血肿。
- 术后3个月随访残留范围与术中结果一致,鞍上区残留体积通常小于术中观察。
研究设计与样本
- 收集并分析137例在1.5T iMRI导航下接受内镜下垂体腺瘤切除术的患者数据。
主要发现
- 92例患者实时iMRI显示完全切除,45例有残留。
- 23例患者行进一步手术,其中19例达到全切除。
- 总切除率从67.15%升至81.02%。
- iMRI发现3例术区出血,均在术中成功处理。
- 术后3个月复查显示26例有残留,其中14例体积与术中相同,12例小于术中;鞍上区15例中11例(73.3%)残留体积小于术中。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Pure endoscopic resection has become the most popular surgical approach for pituitary adenoma. Intraoperative magnetic resonance imaging (iMRI) systems have been in use for endoscopic resection of pituitary adenomas. This study aimed to evaluate the effectiveness of iMRI and neuroimaging navigation techniques during endoscopic endonasal transsphenoidal surgery of pituitary adenomas. METHODS: Data from 137 patients who underwent resection of endoscopic pituitary adenoma under 1.5T iMRI navigation were collected and analyzed. RESULTS: Of patients, 92 underwent complete resection and 45 had residual tumor on real-time iMRI. Twenty-three patients underwent further surgery, and total resection was achieved in 19. Extent of total resection increased from 67.15% to 81.02%. iMRI revealed 3 patients with bleeding in the surgical area, which was successfully treated during the surgery. Review images obtained 3 months after surgery showed 26 patients with residual tumor; 14 patients had the same volume as intraoperatively, and 12 patients had a volume less than that observed intraoperatively. Residual tumor volume in the suprasellar region was less than that seen intraoperatively in 11 of 15 (73.3%) patients. CONCLUSIONS: The use of iMRI and neuronavigation not only leads to a higher rate of tumor resection but also helps in detecting and removing hematomas in the surgical area. Follow-up examinations of extent of residual tumor at 3 months postoperatively were consistent with intraoperative results. Residual tumor volume in the suprasellar region was usually less than that observed intraoperatively.
引用
- Zhang H, Wang F, Zhou T, et al. Analysis of 137 Patients Who Underwent Endoscopic Transsphenoidal Pituitary Adenoma Resection Under High-Field Intraoperative Magnetic Resonance Imaging Navigation. World Neurosurg. 2017. PMID: 28434959. doi:10.1016/j.wneu.2017.04.056
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。