文献速递脑血管病外科神经重症

血流导向装置治疗破裂颅内动脉瘤:单中心经验

Flow diverter devices in ruptured intracranial aneurysms: a single-center experience.
PubMed 文献 · J Neurosurg · 2017-04-07

本单中心回顾性系列评估血流导向装置(FDD)治疗破裂颅内动脉瘤的有效性、安全性和中期随访结果,纳入17例因动脉瘤破裂致蛛网膜下腔出血的患者(12女5男,平均WFNS评分2.9),其中8例为血泡样动脉瘤、9例为夹层动脉瘤。随访期间无再出血,总死亡率12%(2/17),总并发症率12%;15例存活者中12例造影随访显示动脉瘤完全闭塞。作者认为FDD可用于常规手术或血管内治疗困难的破裂动脉瘤患者。

要点

  • 17例破裂动脉瘤(8例血泡样、9例夹层)FDD治疗后无再出血。
  • 总死亡率12%(2/17),总并发症率12%,均与蛛网膜下腔出血相关。
  • 15例存活者中12例造影随访显示动脉瘤完全闭塞。

核心结论

  • FDD可用于常规神经外科或血管内治疗困难的破裂动脉瘤患者。

研究设计与样本

  • 单中心回顾性系列,回顾17例因颅内动脉瘤破裂致蛛网膜下腔出血并接受FDD治疗的患者记录(12女、5男,平均WFNS评分2.9)。
  • 17个破裂动脉瘤中8个为血泡样动脉瘤,其余9个为夹层动脉瘤;SAH至治疗的平均间隔为4.2天。
  • 记录术中及围手术期并发症和死亡,术后6至12个月进行临床和造影随访评估。

主要发现

  • 血管内治疗后无一例破裂动脉瘤再出血。
  • 总死亡率为12%(2/17),2例患者因SAH并发症于数日后死亡。
  • 总并发症率为12%:1例在重新放置脑室外引流期间发生脑实质出血,1例小脑后下动脉动脉瘤患者2周后因脊髓梗死出现截瘫。
  • 15例存活患者中12例造影随访显示动脉瘤完全闭塞;其余3例中1例显示动脉瘤残留,1例因动脉瘤增大再次治疗,1例在造影随访中失访。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE In this single-center series, the authors retrospectively evaluated the effectiveness, safety, and midterm follow-up results of ruptured aneurysms treated by implantation of a flow diverter device (FDD). METHODS The records of 17 patients (12 females, 5 males, average World Federation of Neurosurgical Societies score = 2.9) who presented with subarachnoid hemorrhage (SAH) due to the rupture of an intracranial aneurysm treated with an FDD were retrospectively reviewed. Of 17 ruptured aneurysms, 8 were blood blister-like aneurysms and the remaining 9 were dissecting aneurysms. The mean delay between SAH and treatment was 4.2 days. Intraprocedural and periprocedural morbidity and mortality were recorded. Clinical and angiographic follow-up evaluations were conducted between 6 and 12 months after the procedure. RESULTS None of the ruptured aneurysms re-bled after endovascular treatment. The overall mortality rate was 12% (2/17), involving 2 patients who died after a few days because of complications of SAH. The overall morbidity rate was 12%: 1 patient experienced intraparenchymal bleeding during the repositioning of external ventricular drainage, and 1 patient with a posterior inferior cerebellar artery aneurysm developed paraplegia due to a spinal cord infarction after 2 weeks. The angiographic follow-up evaluations showed a complete occlusion of the aneurysm in 12 of 15 surviving patients; of the 3 remaining cases, 1 patient showed a remnant of the aneurysm, 1 patient was retreated due to an enlargement of the aneurysm, and 1 patient was lost at the angiographic follow-up. CONCLUSIONS FDDs can be used in patients with ruptured aneurysms, where conventional neurosurgical or endovascular treatments can be challenging.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Lozupone E, Piano M, Valvassori L, et al. Flow diverter devices in ruptured intracranial aneurysms: a single-center experience. J Neurosurg. 2017. PMID: 28387623. doi:10.3171/2016.11.JNS161937

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。