术中计算机断层扫描与Nexframe引导下双侧海马响应性神经刺激电极置入:技术说明

Intraoperative Computed Tomography and Nexframe-Guided Placement of Bilateral Hippocampal-Based Responsive Neurostimulation: Technical Note.
PubMed 文献 · World Neurosurg · 2017-02-06

本文回顾性分析4例药物难治性癫痫患者接受双侧内侧颞叶响应性神经刺激(RNS)置入的技术经验,共置入8根电极,随访至6个月。1根电极因向量误差>3 mm而翻修,改良手术技术后所有后续电极均单次置入且向量误差<2 mm。作者初步数据提示双侧颞叶RNS置入具有相似的准确性和安全性。

要点

  • 4例患者共置入8根双侧海马深部电极,随访至6个月。
  • 1根电极因向量误差>3 mm翻修,改良技术后单次置入误差<2 mm。
  • 作者初步数据提示双侧颞叶RNS置入准确性和安全性相似。

核心结论

  • 作者报告了将Nexframe适配于海马深部电极RNS系统置入的技术细节。
  • 作者所在团队在Nexframe用于准确安全的深部脑刺激电极置入方面有丰富经验。
  • 作者的双侧颞叶RNS置入初步数据提示相似的准确性和安全性。

研究设计与样本

  • 回顾性病历 review,纳入4例因药物难治性癫痫接受双侧内侧颞叶RNS置入的患者。
  • 评估并改良手术技术,总结门诊 electrocorticographic 记录及可用数据的亚组分析。

主要发现

  • 4例患者共置入8根电极,随访至6个月。
  • 8根电极中1根因向量误差>3 mm而翻修;改良手术技术后,所有后续电极均单次置入且向量误差<2 mm。
  • 根据患者癫痫日记,癫痫发作症状学与门诊 electrocorticographic 记录模式相关并亚组分析:51.4%为左侧,15%为右侧,33.6%为不确定。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Surgical resection of a lesion that correlates with seizure onset in patients with epilepsy can dramatically improve seizure burden and quality of life. For bilateral hippocampal lesions, bilateral resection comes with a risk of severe cognitive deficits. Responsive neurostimulation (RNS) devices offer a new modality to treat multifocal lesions in a reversible manner including bilateral hippocampal stimulation. We describe technical aspects of Nexframe-assisted placement of bilateral NeuroPace mesial temporal electrodes and case examples. METHODS: Retrospective chart review was performed for 4 patients who underwent bilateral mesial temporal RNS placement for medically intractable epilepsy. Operative techniques were assessed and modified. Ambulatory electrocorticographic recordings and a subanalysis of available data are summarized. RESULTS: Eight electrodes were placed in 4 patients, who were followed for up to 6 months. One out of 8 electrodes was revised due to vector error >3 mm; after surgical technique modification, all subsequent electrodes were reliably placed in a single pass with <2-mm vector error. Using patients' seizure diaries, seizure semiologies were correlated with ambulatory ECoG recording patterns and subanalyzed; 51.4% were left sided, 15% were right sided, and 33.6% were indeterminate. CONCLUSIONS: We report herein the technical nuances of adapting Nexframe to hippocampal-based depth electrode RNS system placement. Our group has extensive experience with Nexframe for accurate and safe deep brain stimulation electrode placement. Our preliminary data with bitemporal RNS placement suggest similar accuracy and safety.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Gupta K, Raskin JS, Raslan AM, et al. Intraoperative Computed Tomography and Nexframe-Guided Placement of Bilateral Hippocampal-Based Responsive Neurostimulation: Technical Note. World Neurosurg. 2017. PMID: 28185967. doi:10.1016/j.wneu.2017.01.109

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。