文献速递神经肿瘤功能神经外科

基于弥散张量成像的皮质脊髓束纤维束成像评估:与术中磁共振成像及直接电刺激的相关性研究

Evaluation of Diffusion Tensor Imaging-Based Tractography of the Corticospinal Tract: A Correlative Study With Intraoperative Magnetic Resonance Imaging and Direct Electrical Subcortical Stimulation.
PubMed 文献 · Neurosurgery · 2017-01-01

这项前瞻性相关性研究纳入20例邻近皮质脊髓束的胶质瘤(II-IV级)患者,在1.5-T术中磁共振下于术前和术中行双侧皮质脊髓束弥散张量成像纤维束成像,并与直接电刺激下皮质下刺激这一金标准进行对比。结果显示纤维束成像定位皮质脊髓束的敏感度为100%、特异度为72%、阳性预测值为78%、阴性预测值为100%,且刺激强度与距离呈线性相关,作者认为其高敏感度有助于定位邻近切除腔的皮质脊髓束。

要点

  • 纤维束成像定位皮质脊髓束的敏感度100%、特异度72%、阳性预测值78%、阴性预测值100%。
  • 纤维束成像与86%的直接电刺激结果一致性良好,刺激强度与距离呈线性相关。
  • 全部患者临床改善,平均切除程度97.2%;作者认为需更大样本前瞻性研究进一步支持。

核心结论

  • 在术中磁共振环境下,皮质脊髓束可视化在胶质瘤手术中定位邻近切除腔的皮质脊髓束区域似乎具有高敏感度。
  • 作者认为需要更多大样本前瞻性研究来进一步支持该结果。

研究设计与样本

  • 前瞻性相关性研究,纳入20例邻近皮质脊髓束的胶质瘤(II-IV级)患者。
  • 于术前和术中应用1.5-T术中磁共振行双侧皮质脊髓束弥散张量成像纤维束成像,并与直接电刺激下皮质下刺激这一现行金标准进行相关和比较。
  • 采用敏感度、特异度、阳性预测值和阴性预测值量化纤维束成像与直接电刺激的相关性,并分析刺激强度与距皮质脊髓束距离的关系。
  • 用5-氨基乙酰丙酸评估切除腔壁刺激点的组织质量,并分析术后及随访期的临床与体积学结局。

主要发现

  • 患者平均年龄54.9±12岁。
  • 共重建40条皮质脊髓束,在20条病理皮质脊髓束上纳入36次刺激,结果为18次真阳性、5次假阳性和13次真阴性。
  • 纤维束成像定位皮质脊髓束的敏感度为100%、特异度为72%、阳性预测值为78%、阴性预测值为100%。
  • 纤维束成像与86%的直接电刺激结果一致性良好,刺激强度与距离之间检出线性相关。
  • 全部患者临床改善,平均切除程度为97.2%;5-氨基乙酰丙酸在假阳性病例中有助于显示肿瘤浸润,提示刺激点处皮质脊髓束受浸润。

临床怎么用

  • 作者认为术中磁共振环境下的皮质脊髓束可视化在胶质瘤手术中定位邻近切除腔的皮质脊髓束区域似乎具有高敏感度。
  • 作者认为需要更多大样本前瞻性研究来进一步支持该结果。

局限性

  • 作者指出需要更多大样本前瞻性研究来进一步支持该结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The accuracy of intraoperative diffusion tensor imaging (DTI)–based tractography of the corticospinal tract (CST) is crucial for its use in neurosurgical planning and its implementation in image-guided surgery. To the best of our knowledge, this is the largest prospective correlative study of the intraoperative DTI tractography of the CST and intraoperative direct electrical subcortical stimulation (DESS) of the CST, with application of intraoperative magnetic resonance imaging (iMR). OBJECTIVE: To evaluate intraoperatively acquired DTI-based tractography of the CST in correlation with DESS. METHODS: Twenty patients with gliomas (grades II-IV) adjacent to the CST were included in this prospective study. Bilateral DTI tractography of the CST was performed pre- and intraoperatively with application of 1.5-T iMRI and the results correlated and compared with the prevailing gold standard of DESS. Sensitivity, specificity, positive predictive value, and negative predictive value were considered to quantify the correlation of DTI tractography with DESS. The intensity of DESS was correlated with the distance from the CST. Moreover, the tissue quality of stimulation points at the wall of the resection cavity was evaluated with 5-aminolevulinic acid. The clinical and volumetric outcomes at postoperative and follow-up periods were also analyzed. RESULTS: The mean ± SD age of the patients was 54.9 ± 12 years. A total of 40 CSTs were reconstructed and 36 stimulations were included at 20 pathological CSTs, resulting in 18 true-positive, 5 false-positive, and 13 true-negative responses. The sensitivity, specificity, positive predictive value, and negative predictive value of DTI tractography to localize the CST were 100%, 72%, 78%, and 100%, respectively. DTI-based tractography correlated well at 86% of DESSs, and a linear correlation was detected between the intensity of DESS and the distance. All of the patients improved clinically, and the mean extent of resection was 97.2%. 5-Aminolevulinic acid was valuable in visualizing tumor infiltration in the false-positive cases, suggesting an infiltration of the CST at stimulation points. CONCLUSION: CST visualization in the iMRI setting appears to have a high sensitivity in accurately localizing the area of the CST adjacent to the resection cavity in glioma surgery. More prospective studies with a large sample size are needed to further support the results.

来源:Neurosurgery,查看原文。版权归原作者所有。

引用

  1. Javadi SA, Nabavi A, Giordano M, et al. Evaluation of Diffusion Tensor Imaging-Based Tractography of the Corticospinal Tract: A Correlative Study With Intraoperative Magnetic Resonance Imaging and Direct Electrical Subcortical Stimulation. Neurosurgery. 2017. PMID: 28175893. doi:10.1227/NEU.0000000000001347

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。