分形分析或可改善非典型脑膜瘤的术前识别
本研究纳入27例非典型(WHO II级)与27例良性(WHO I级)脑膜瘤患者,对术前钆增强T1加权MR图像采用盒计数法计算肿瘤强化区的平均分形维数(FDa)和最大分形维数(FDm),并纳入逻辑回归模型分析。结果显示非典型组分形维数显著高于良性组,FDm>1.31与非颅底位置是非典型表型的显著预测因素。
要点
- 分形分析在术前MR图像上显示良好的观察者间可重复性(Kappa>0.70)。
- 非典型脑膜瘤的FDa和FDm均显著高于良性脑膜瘤(P<.0001)。
- FDm>1.31(OR 12.30,P=.039)与非颅底位置(OR .052,P=.015)是非典型表型的显著预测因素。
核心结论
- 术前MR图像的分形分析似乎是一种可行的辅助诊断工具,可用于识别具有潜在侵袭性临床行为的脑膜瘤。
研究设计与样本
- 纳入27例非典型(WHO II级)脑膜瘤患者和27例良性(WHO I级)脑膜瘤患者,对术前钆增强T1加权MR图像进行处理和分析。
主要发现
- 队列共34名女性和20名男性,平均年龄62±15岁。
- 分形分析显示良好的观察者间可重复性(Kappa>0.70)。
- 非典型脑膜瘤组的FDa和FDm均显著高于良性脑膜瘤组(P<.0001)。
- 多变量逻辑回归模型达到统计学显著性,P=.0001,AUC=0.87。
- FDm大于1.31(OR 12.30;P=.039)和非颅底位置(OR .052;P=.015)被确认为非典型表型的统计学显著预测因素。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: There is no objective and readily accessible method for the preoperative determination of atypical characteristics of a meningioma grade. OBJECTIVE: To evaluate the feasibility of using fractal analysis as an adjunctive tool to conventional radiological techniques in visualizing histopathological features of meningiomas. METHODS: A group of 27 patients diagnosed with atypical (WHO grade II) meningioma and a second group of 27 patients with benign (WHO grade I) meningioma were enrolled in the study. Preoperative brain magnetic resonance (MR) studies (T1-wieghted, post-gadolinium) were processed and analyzed to determine the average fractal dimension (FDa) and maximum fractal dimension (FDm) of the contrast-enhancing region of the tumor using box-count method. FDa and FDm as well as particular radiological features were included in the logistic regression model as possible predictors of malignancy. RESULTS: The cohort consisted of 34 women and 20 men, mean age of 62 ± 15 yr. Fractal analysis showed good interobserver reproducibility (Kappa >0.70). Both FDa and FDm were significantly higher in the atypical compared to the benign meningioma group (P < .0001). Multivariate logistic regression model reached statistical significance with P = .0001 and AUC = 0.87. The FDm, which was greater than 1.31 (odds ratio [OR], 12.30; P = .039), and nonskull base localization (OR, .052; P = .015) were confirmed to be statistically significant predictors of the atypical phenotype. CONCLUSION: Fractal analysis of preoperative MR images appears to be a feasible adjunctive diagnostic tool in identifying meningiomas with potentially aggressive clinical behavior.
引用
- Czyz M, Radwan H, Li JY, et al. Fractal Analysis May Improve the Preoperative Identification of Atypical Meningiomas. Neurosurgery. 2017. PMID: 28173535. doi:10.1093/neuros/nyw030
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。