CT血管造影与数字减影血管造影在破裂动脉瘤诊断中的比较
该单中心回顾性队列纳入643例患者,其中401例同时接受CTA和确诊性DSA检查。CTA检出330个动脉瘤,DSA检出431个,CTA总体敏感度70.7%,对小于5 mm动脉瘤敏感度57.6%,对颈内动脉起源动脉瘤敏感度45%。作者认为CTA诊断破裂颅内动脉瘤的准确性可能低于既往报道,单独使用时应谨慎。
要点
- CTA在蛛网膜下腔出血(SAH)背景下诊断破裂颅内动脉瘤的总体敏感度为70.7%。
- CTA对直径小于5 mm的动脉瘤敏感度为57.6%,对颈内动脉起源动脉瘤敏感度为45%。
- DSA检出而CTA漏诊的125个动脉瘤中,83.2%直径小于5 mm。
核心结论
- CTA诊断破裂颅内动脉瘤的准确性可能低于既往报道。
- CTA对小于5 mm、邻近骨性结构及起源于小口径载瘤血管的动脉瘤敏感度低。
- 作者建议单独使用CTA诊断破裂颅内动脉瘤时应谨慎。
研究设计与样本
- 单中心回顾性队列研究,共审查643例患者。
- 其中401例患者的诊断检查同时包括CTA和确诊性数字减影血管造影(DSA)。
- 对CTA漏诊而DSA诊断的动脉瘤按大小和位置进一步分层分析。
主要发现
- CTA检出330个动脉瘤,DSA共检出431个动脉瘤。
- CTA假阳性结果见于24个动脉瘤。
- DSA识别出125个CTA漏诊的动脉瘤,其中83.2%直径小于5 mm。
- CTA对小于5 mm动脉瘤的敏感度为57.6%,对颈内动脉起源动脉瘤的敏感度为45%。
- CTA在SAH背景下的总体敏感度为70.7%。
临床怎么用
- 作者建议单独使用CTA诊断破裂颅内动脉瘤时应谨慎。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Computerized tomography angiography (CTA) is commonly used to diagnose ruptured cerebral aneurysms with sensitivities reported as high as 97% to 100%. Studies validating CTA accuracy in the setting of subarachnoid hemorrhage (SAH) are scarce and limited by small sample sizes. OBJECTIVE: To evaluate the diagnostic accuracy of CTA in detecting intracranial aneurysms in the setting of SAH. METHODS: A single-center, retrospective cohort of 643 patients was reviewed. A total of 401 patients were identified whose diagnostic workup included both CTA and confirmatory digital subtraction angiography (DSA). Aneurysms missed by CTA but diagnosed by DSA were further stratified by size and location. RESULTS: Three hundred and thirty aneurysms were detected by CTA while DSA detected a total of 431 aneurysms. False positive CTA results were seen for 24 aneurysms. DSA identified 125 aneurysms that were missed by CTA and 83.2% of those were <5 mm in diameter. The sensitivity of CTA was 57.6% for aneurysms smaller than 5 mm in size, and 45% for aneurysms originating from the internal carotid artery. The overall sensitivity of CTA in the setting of SAH was 70.7%. CONCLUSION: The accuracy of CTA in the diagnosis of ruptured intracranial aneurysm may be lower than previously reported. CTA has a low sensitivity for aneurysms less than 5 mm in size, in locations adjacent to bony structures, and for those arising from small caliber parent vessels. It is our recommendation that CTA should be used with caution when used alone in the diagnosis of ruptured intracranial aneurysms.
引用
- Philipp LR, McCracken DJ, McCracken CE, et al. Comparison Between CTA and Digital Subtraction Angiography in the Diagnosis of Ruptured Aneurysms. Neurosurgery. 2017. PMID: 28201559. doi:10.1093/neuros/nyw113
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。