文献速递小儿神经外科与脑积水神经重症

择期颅内压监测:多长时间才算足够?

Elective ICP monitoring: how long is long enough?
PubMed 文献 · Acta Neurochir (Wien) · 2017-01-20

该回顾性审计比较了18例择期成人患者24小时、48小时及总监测时长的颅内压(ICP)中位数和脉冲振幅中位数。结果显示24小时与48小时或更长时间之间均无统计学差异,作者认为使用Spiegelberg脑实质螺栓监测24小时即可准确反映ICP动力学。

要点

  • 择期ICP监测24小时与48小时或更长时间的总体ICP中位数和脉冲振幅无统计学差异。
  • 作者所在机构目前对疑似ICP异常患者至少采集48小时数据。
  • 18例患者中无因ICP监测出现的并发症。

核心结论

  • 使用Spiegelberg脑实质螺栓对择期成人患者进行24小时ICP监测即可准确反映其ICP动力学,与更长时间监测相比无统计学差异。

研究设计与样本

  • 回顾性审计,纳入6个月期间符合纳入/排除标准的18例择期ICP监测患者,比较24小时、48小时及总分析时长的总体ICP中位数和总体脉冲振幅中位数,采用配对T检验评估差异。

主要发现

  • 18例患者中位年龄45.8岁(范围22-83岁),女性12例、男性6例,诊断包括正常压力脑积水(NPH)、特发性颅内高压(IIH)、疑似分流功能障碍和Chiari畸形。
  • 未发生因ICP监测导致的并发症。
  • 24小时与48小时或更长时间监测之间,总体ICP中位数和脉冲振幅均无统计学差异。

临床怎么用

  • 作者所在机构目前对疑似ICP异常患者至少采集48小时数据。
  • 作者认为择期成人患者使用Spiegelberg脑实质螺栓监测24小时即可准确反映ICP动力学。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intracranial pressure monitoring is commonly undertaken to assess and manage acute patients following head injury. However, ICP monitoring can also be a useful diagnostic tool in the management of CSF dynamics in elective patients. To date, there is little published research to suggest how long these elective patients require ICP monitoring in order to gain an accurate picture of a patient's ICP dynamics. At the author's institution, a minimum of 48-h data collection is currently undertaken in patients with a suspected ICP abnormality. METHODS: A retrospective audit was undertaken comparing overall median ICP and overall median pulse amplitude data at three time points, 24 h, 48 h and total time analysed (if longer than 48 h). Paired T-test was used to assess if there were statistically significant differences between 24-h versus 48-h monitoring and total duration of monitoring. All patients admitted over a 6-month period for ICPM who met the inclusion/exclusion criteria were included. RESULTS: Eighteen patients met the criteria. Median age was 45.8 years, range 22-83 years, 12 female and 6 male. No complications were experienced as a result of ICPM. Diagnosis included NPH, IIH, suspected shunt malfunction and Chiari malformation. The results demonstrated that there is no statistical difference between 24 h and 48 h or longer for both overall median ICP and pulse amplitude. CONCLUSION: The results of this study demonstrate that ICP monitoring of elective adult patients using a Spiegelberg intraparenchymal bolt for 24 h gives an accurate picture of a patient's ICP dynamics compared with longer periods of monitoring.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Thompson SD, Coutts A, Craven CL, et al. Elective ICP monitoring: how long is long enough? Acta Neurochir (Wien). 2017. PMID: 28108854. doi:10.1007/s00701-016-3074-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。