立体定向脑电图是安全的手术,包括岛叶植入
该研究回顾性分析1995至2015年间525例连续立体定向脑电图(SEEG)手术,按电极轨迹分为岛叶与岛叶外两组,比较颅内血肿风险并报告总体安全性。结果显示4例脑实质内血肿均与岛叶外电极相关(4/4974;0.08%),岛叶电极未见血肿(0/1042;0%)。结论认为SEEG是安全的手术,岛叶轨迹不构成额外颅内出血风险。
要点
- 4例脑实质内血肿均与岛叶外电极相关(4/4974;0.08%),岛叶电极未见血肿(0/1042;0%)。
- 8例主要并发症(1.52%):7例颅内血肿(1.33%)和1例脑膜炎。
- 2例长期神经功能缺损(0.38%),1例死亡(与手术无直接关系)(0.19%)。
核心结论
- SEEG是安全的手术,岛叶轨迹不能被认为是颅内出血的额外风险。
研究设计与样本
- 回顾性分析1995年至2015年间525例连续SEEG手术,所有电极按岛叶或岛叶外轨迹分类,并发症按对患者神经状态的潜在后果分为主要或次要。
主要发现
- 4例脑实质内血肿均与岛叶外电极相关(4/4974;0.08%),岛叶电极未见血肿(0/1042;0%)。
- 8例主要并发症(1.52%):7例颅内血肿(1.33%)和1例脑膜炎。
- 2例长期神经功能缺损(0.38%),1例死亡(与手术无直接关系)(0.19%)。
- 11例次要并发症(2.09%),包括电极断裂(1.52%)、急性气颅(0.38%)和局部皮肤感染(0.19%)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In some cases of drug-resistant focal epilepsy, noninvasive presurgical investigation may be insufficient to identify the ictal onset zone and the eloquent cortical areas. In such situations, invasive investigations are proposed using either stereotactic electroencephalography (SEEG) or subdural grid electrodes. Meta-analysis suggests that SEEG is safer than subdural grid electrodes, but insular implantation of SEEG electrodes has been thought to carry an additional risk of intraparenchymal hemorrhagic complications. Our objectives were to determine whether an insular SEEG trajectory is a risk factor for intracranial hematoma and to report the global safety of the procedure and provide some guidelines to prevent and detect complications. METHODS: In a retrospective analysis of a surgical series of 525 consecutive procedures between 1995 and 2015, all electrodes were classified according to their insular or extrainsular trajectory. All complications were classified as major or minor according to their potential consequences regarding patient neurologic status. RESULTS: Four intraparenchymal hematomas, all related to extrainsular electrodes (4/4974; 0.08%) were reported; no hematoma was found along insular electrodes (0/1042; 0%). There were 8 major complications (1.52%): 7 intracranial hematomas (1.33%) and 1 case of meningitis. Two patients had long-term neurologic impairment (0.38%), and 1 death (not directly related to the procedure) occurred (0.19%). Eleven minor complications (2.09%) were encountered, including broken electrode (1.52%), acute pneumocephalus (0.38%), and local cutaneous infection (0.19%). CONCLUSIONS: SEEG is a safe procedure. Insular trajectories cannot be considered an additional risk of intracranial bleeding.
引用
- Bourdillon P, Ryvlin P, Isnard J, et al. Stereotactic Electroencephalography Is a Safe Procedure, Including for Insular Implantations. World Neurosurg. 2016. PMID: 28003163. doi:10.1016/j.wneu.2016.12.025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。