文献速递脑血管病外科

载瘤动脉的变直效应在大型动脉瘤支架辅助弹簧圈栓塞中降低再通的作用

Contribution of the straightening effect of the parent artery to decreased recanalization in stent-assisted coiling of large aneurysms.
PubMed 文献 · J Neurosurg · 2016-12-23

本研究从182个经栓塞治疗的动脉瘤中选取82个直径大于7 mm的连续未破裂动脉瘤,其中52个采用支架辅助栓塞(S组),30个未用支架(NS组),12个月后行数字减影血管造影评估闭塞状态并测量载瘤动脉血管角度。S组主要再通率为9.6%,NS组为26.7%;S组栓塞前后角度变化为10.6°,NS组为0.9°,12个月后分别为19.1°和1.5°。S组中角度变化≥20°的17个动脉瘤全部保持闭塞,而无显著角度变化的35个动脉瘤再通率为14.3%。结论认为角度变化≥20°最可能导致大型动脉瘤支架辅助栓塞后再通减少。

要点

  • S组主要再通率为9.6%,NS组为26.7%。
  • S组栓塞前后角度变化为10.6°,NS组为0.9°。
  • S组中角度变化≥20°的动脉瘤全部保持闭塞。

核心结论

  • 角度变化≥20°最可能导致大型动脉瘤支架辅助栓塞后再通减少。

研究设计与样本

  • 从182个经栓塞治疗的动脉瘤中选取82个直径大于7 mm的连续未破裂动脉瘤,其中52个采用支架辅助栓塞(S组),30个未用支架(NS组)。

主要发现

  • S组主要再通率为9.6%,NS组为26.7%。
  • S组体积栓塞率为32.6%,NS组为31.6%,差异无统计学意义。
  • S组栓塞前后角度变化为10.6°,NS组为0.9°;12个月后分别为19.1°和1.5°。
  • S组中无显著角度变化(以角度变化大于20°为显著)的35个动脉瘤再通率为14.3%,而角度变化≥20°的17个动脉瘤全部保持闭塞。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE The durability of embolization of large aneurysms is enhanced by use of the neck-bridging stent. However, it remains unclear what factors contribute to decreased recanalization. The purpose of this study was to demonstrate the contribution of the straightening effect of the parent artery to the durability of stent-assisted coiling for large aneurysms. METHODS Of the 182 aneurysms treated by embolization since the introduction of the neurovascular stent, 82 consecutive unruptured aneurysms with a diameter greater than 7 mm were selected. There were 52 aneurysms treated with a stent (Group S) and 30 treated without a stent (Group NS). Occlusion status was evaluated 12 months after embolization with digital subtraction angiography. The vascular angle of the parent artery was measured before, immediately after, and 12 months after embolization. The rates of recanalization were compared between Group S and Group NS. In Group S, the rates of recanalization were further compared between those aneurysms with and without a significant angle change. RESULTS The rate of major recanalization was 9.6% in Group S and 26.7% in Group NS. The volume embolization ratio was 32.6% in Group S and 31.6% in Group NS, with no statistically significant difference. However, the angulation change before and after coiling was significantly higher in Group S (10.6°) than in Group NS (0.9°). The difference in the angulation was more evident 12 months after coiling (19.1° in Group S and 1.5° in Group NS). In Group S, recanalization was found in 14.3% of 35 stented aneurysms without a significant angular change when a significant angular change was defined as more than 20°. In contrast, all 17 aneurysms with ≥ 20° of angular change remained occluded. CONCLUSIONS Significant angular change of ≥ 20° most likely leads to decreased recanalization following stent-assisted embolization of large aneurysms.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Ishii A, Chihara H, Kikuchi T, et al. Contribution of the straightening effect of the parent artery to decreased recanalization in stent-assisted coiling of large aneurysms. J Neurosurg. 2016. PMID: 28009233. doi:10.3171/2016.9.JNS16501

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。