文献速递脑血管病外科

PulseRider治疗宽颈分叉部颅内动脉瘤的6个月结果

PulseRider for Treatment of Wide-Neck Bifurcation Intracranial Aneurysms: 6-Month Results.
PubMed 文献 · World Neurosurg · 2016-12-23

这项回顾性研究纳入6个欧洲中心和1个美国中心的19例未破裂宽颈分叉部颅内动脉瘤患者,使用PulseRider辅助弹簧圈栓塞。6个月随访时完全闭塞12例(63.1%),颈部残留6例(31.6%),残留动脉瘤1例(5.3%),充分闭塞率为94.7%,永久致残率5.3%(1/19),死亡率为0%。作者认为PulseRider可用于宽颈分叉部颅内动脉瘤的血管内治疗,但需更大样本证实初步结果。

要点

  • 6个月随访完全闭塞12例(63.1%),颈部残留6例(31.6%),残留动脉瘤1例(5.3%)。
  • 充分闭塞(完全闭塞+颈部残留)率为94.7%,进行性血栓形成2例(10.6%),再通1例(5.3%)。
  • 永久致残率5.3%(1/19),死亡率0%,无支架内狭窄或分支闭塞,随访期无出血。

核心结论

  • PulseRider可用于宽颈分叉部颅内动脉瘤的血管内治疗,但需更大样本证实初步结果。

研究设计与样本

  • 回顾性研究,纳入2014年6月至2015年10月期间6个欧洲中心和1个美国中心使用PulseRider辅助弹簧圈栓塞的未破裂颅内动脉瘤患者19例(女10例,男9例;平均年龄63岁),共19个分叉部动脉瘤(平均瘤顶尺寸8.8 mm,平均瘤颈尺寸5.8 mm)。
  • 即刻和6个月结果由研究者独立采用Raymond分级量表评估,再通定义为Raymond分级恶化,进行性血栓形成定义为Raymond分级改善。

主要发现

  • 即刻血管造影结果显示完全闭塞11例,颈部残留6例,残留动脉瘤2例。
  • 6个月随访所有患者均获得,完全闭塞12例(63.1%),颈部残留6例(31.6%),残留动脉瘤1例(5.3%)。
  • 充分闭塞(完全闭塞和颈部残留合计)见于94.7%。
  • 进行性血栓形成2例(10.6%),再通1例(5.3%)。
  • 无支架内狭窄或分支闭塞,随访期间无出血,永久致残率5.3%(1/19),6个月死亡率0%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论指出需更大样本证实初步结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/OBJECTIVE: PulseRider is a new endovascular stent dedicated to treat bifurcation intracranial aneurysms with a wide neck. Our purpose was to evaluate 6-month clinical and anatomic results of the device when used to facilitate endovascular coiling of wide-neck bifurcation aneurysms. METHODS: Unruptured intracranial aneurysms coiled with PulseRider, in 6 European centers and 1 U.S. center, were retrospectively reviewed from June 2014 to October 2015. Immediate and 6-month results were evaluated independently by using the Raymond classification scale. Recanalization was defined as worsening, and progressive thrombosis was defined as improvement on the Raymond scale. RESULTS: Nineteen patients (10 women, 9 men; mean age, 63 years) harboring 19 bifurcation aneurysms (mean dome size, 8.8 mm; mean neck size, 5.8 mm) were included. Immediate angiographic outcome showed 11 complete aneurysm occlusions, 6 neck remnants, and 2 residual aneurysms. Follow-up at 6 months, obtained in all patients, included 12 complete aneurysm occlusions (63.1%), 6 neck remnants (31.6%), and 1 residual aneurysm (5.3%). Adequate occlusion (defined as complete occlusion and neck remnant combined) was observed in 94.7%. Progressive thrombosis was observed in 2 cases (10.6%) and recanalization in 1 case (5.3%). There was no in-stent stenosis or jailed branch occlusion. No bleeding was observed during the follow-up period. Permanent morbidity rate was 5.3% (1/19), and the mortality rate was 0% at 6 months. CONCLUSIONS: The PulseRider allows endovascular treatment of wide-neck bifurcation intracranial aneurysms. Larger series are needed to confirm our preliminary results.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Gory B, Spiotta AM, Di Paola F, et al. PulseRider for Treatment of Wide-Neck Bifurcation Intracranial Aneurysms: 6-Month Results. World Neurosurg. 2016. PMID: 28017750. doi:10.1016/j.wneu.2016.12.065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。