三维稳态构成干扰序列与相位对比磁共振成像在静止性脑积水中的评估
前瞻性研究纳入20例静止性脑积水患者,评估3D-CISS与PC-MRI对导水管通畅性及脑脊液流量的评估价值。梗阻病因为导水管梗阻75%(n=15)、第三脑室梗阻5%(n=1)、第四脑室梗阻20%(n=4);静止原因包括自发性第三脑室造瘘65%(n=13)、内镜下第三脑室造瘘10%(n=2)、脑室腹腔分流5%(n=1),20%(n=4)未检出原因。两种序列分级呈正相关(r=0.80)和中等一致(κ=0.509)。
要点
- 3D-CISS与PC-MRI可用于无创评估静止性脑积水的梗阻平面和原因。
- 导水管梗阻是最常见病因,占75%(n=15)。
- 自发性第三脑室造瘘是静止最常见原因,占65%(n=13)。
核心结论
- 3D-CISS和PC-MRI是无创序列,可用于诊断静止性脑积水的梗阻平面和原因。
研究设计与样本
- 前瞻性研究,纳入20例静止性脑积水患者,所有患者均接受PC-MRI和3D-CISS评估导水管。
主要发现
- 梗阻病因为导水管梗阻75%(n=15)、第三脑室梗阻5%(n=1)、第四脑室梗阻20%(n=4)。
- 静止原因包括自发性第三脑室造瘘65%(n=13)、内镜下第三脑室造瘘10%(n=2)、脑室腹腔分流5%(n=1),20%(n=4)未检出原因。
- PC-MRI与3D-CISS分级呈正相关(r=0.80)和中等一致(κ=0.509)。
- 脑脊液收缩期峰值流速均值为1.86 ± 2.48 cm/秒,每周期搏出量为6.43 ± 13.81 μL/周期,平均流量为0.21 ± 0.32 mL/分钟。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the role of three-dimensional constructive interference in steady state (3D-CISS) sequences and phase-contrast magnetic resonance imaging (PC-MRI) in patients with arrested hydrocephalus. METHODS: A prospective study of 20 patients with arrested hydrocephalus was carried out. All patients underwent PC-MRI and 3D-CISS for assessment of the aqueduct. Axial (through-plane), sagittal (in-plane) PC-MRI, and sagittal 3D-CISS were applied to assess the cerebral aqueduct and the spontaneous third ventriculostomy if present. Aqueductal patency was graded using 3D-CISS and PC-MRI. Quantitative analysis of flow through the aqueduct was performed using PC-MRI. RESULTS: The causes of obstruction were aqueductal obstruction in 75% (n = 15), third ventricular obstruction in 5% (n = 1), and fourth ventricular obstruction in 20% (n = 4). The cause of arrest of hydrocephalus was spontaneous third ventriculostomy in 65% (n = 13), endoscopic third ventriculostomy in 10% (n = 2), and ventriculoperitoneal shunt in 5% (n = 1), and no cause could be detected in 20% of patients (n = 4). There is a positive correlation (r = 0.80) and moderate agreement (κ = 0.509) of grading with PC-MRI and 3D-CISS sequences. The mean peak systolic velocity of cerebrospinal fluid was 1.86 ± 2.48 cm/second, the stroke volume was 6.43 ± 13.81 μL/cycle, and the mean flow was 0.21 ± 0.32 mL/minute. CONCLUSIONS: We concluded that 3D-CISS and PC-MRI are noninvasive sequences for diagnosis of the level and cause of arrested hydrocephalus.
引用
- Elkafrawy F, Reda I, Elsirafy M, et al. Three-Dimensional Constructive Interference in Steady State Sequences and Phase-Contrast Magnetic Resonance Imaging of Arrested Hydrocephalus. World Neurosurg. 2016. PMID: 27826087. doi:10.1016/j.wneu.2016.10.140
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。