多模态颅内监测背景下的硬膜下积脓
一例32岁男性遭受攻击后格拉斯哥昏迷评分8分,转入本院时为7T,行Integra Licox脑组织氧监测和Hemedex Bowman灌注监测等多模态颅内监测,并因颅内压升高放置脑室外引流。患者颅内压恢复正常,但期间因发热和耐甲氧西林金黄色葡萄球菌使用抗生素,随后发生多灶性硬膜下积脓需手术清除,术后培养无细菌生长,可能与2周广谱抗生素使用有关。作者称这是该背景下首例硬膜下积脓报道,提醒神经外科医生警惕感染并发症。
要点
- 多模态颅内监测虽安全,但随侵入性床旁操作增多,需警惕感染并发症。
- 本例32岁男性在多模态监测期间发生多灶性硬膜下积脓,需手术清除。
- 术后培养无细菌生长,可能与2周广谱抗生素使用有关。
核心结论
- 据作者所知,这是首例在多模态颅内监测背景下发生硬膜下积脓的报道。
- 作者认为多模态颅内监测的安全性良好,但随侵入性床旁操作增多,神经外科医生必须高度警惕感染并发症的发生。
研究设计与样本
- 病例报告:一例32岁男性,遭受攻击后初始在外院格拉斯哥昏迷评分为8分,转入本院时为7T。
主要发现
- 患者转入本院后格拉斯哥昏迷评分为7T,实施Integra Licox脑组织氧监测和Hemedex Bowman灌注监测,并在标准颅内压监测显示颅内压升高时放置脑室外引流。
- 患者颅内压恢复正常,但期间因发热和耐甲氧西林金黄色葡萄球菌需使用抗生素。
- 患者随后发生多灶性硬膜下积脓,需手术清除。
- 术后术中培养无细菌生长,可能与2周广谱抗生素使用有关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Multimodal intracranial monitoring is becoming an increasingly common tool in the management of patients with traumatic brain injury. Although numerous reports detailing the benefits of such advanced monitoring exist in the literature, there is minimal discussion of the possible complications that may arise in this patient population. CASE DESCRIPTION: We report the case of a 32-year-old patient who had been assaulted and presented initially at an outside facility with a Glasgow Coma Scale score of 8. After transfer to our hospital, his Glasgow Coma Scale score was noted at 7T and multimodal monitoring with the Integra Licox brain tissue oxygen monitor and the Hemedex Bowman perfusion monitor was implemented, along with an external ventricular drain when a standard intracranial pressure monitor indicated increasing intracranial pressure. The patient's intracranial pressure normalized but he did require a course of antibiotics during this time for a fever and methicillin-resistant Staphylococcus aureus. The patient subsequently developed multifocal subdural empyemas requiring surgical evacuation. Postoperatively, the patient's intraoperative cultures remained without bacterial growth, likely related to the 2-week broad-spectrum antibiotic use. CONCLUSIONS: To our knowledge, this is the first reported incidence of a subdural empyema developing in this setting. Although the safety profile of multimodal intracranial modeling is excellent, with increasing numbers of invasive bedside procedures, neurosurgeons must remain acutely vigilant for the development of infectious complications.
引用
- Guan J, Spivak ES, Wilkerson C, et al. Subdural Empyema in the Setting of Multimodal Intracranial Monitoring. World Neurosurg. 2016. PMID: 27826090. doi:10.1016/j.wneu.2016.10.133
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。