去骨瓣减压术后床旁经颅超声与头颅CT诊断效能的对比研究
BTUS对血肿灵敏度达100%,对水肿灵敏度最低为59.4%,特异度94.2%至100%,多数并发症κ>0.8,阴性预测值均>80%。结论认为BTUS可作为神经重症一线筛查与监测工具,但不能完全替代CT。
要点
- BTUS对血肿灵敏度100%,对水肿灵敏度最低59.4%,特异度94.2%至100%。
- 多数并发症BTUS与CT一致性κ>0.8,所有主要并发症阴性预测值>80%。
- BTUS适合作为DC术后一线筛查与监测,复杂病例仍需CT确认。
核心结论
- BTUS对DC术后并发症诊断准确率高,可作为神经重症一线筛查与监测工具,但不能完全替代CT。
研究设计与样本
- 每例在CT检查前进行床旁经骨窗超声(BTUS),以头颅CT为参考标准比较两种模态的发现。
主要发现
- BTUS总体灵敏度范围为59.4%(水肿)至100%(血肿),特异度范围为94.2%至100%。
- 多数并发症观察到强或几乎完美的一致性(κ>0.8)。
- 假阴性率在占位性病变最低,在水肿等弥漫性病变最高。
- 所有主要并发症类型的阴性预测值均保持在80%以上。
关键数值与推荐
- BTUS识别血肿灵敏度100%,识别水肿灵敏度59.4%。
- BTUS特异度范围为94.2%至100%。
- 多数并发症κ>0.8,所有主要并发症阴性预测值>80%。
临床怎么用
- 在神经重症监护中可将BTUS作为DC术后并发症的初始检测与监测手段。
- 对不稳定或辐射敏感患者,BTUS可减少对CT扫描的依赖。
- 将常规BTUS纳入DC术后监测方案可能提高患者安全、加快诊断并优化资源利用。
局限性
- 回顾性研究设计。
- 样本量为88例连续患者。
- BTUS在复杂病例中不能完全替代CT。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The aim of this study was to evaluate the diagnostic effectiveness and accuracy of bedside transcranial ultrasonography performed through the craniectomy in diagnosing typical post-decompressive craniectomy (DC) complications, using cranial CT as the reference standard. METHODS: This retrospective study analyzed 88 consecutive patients who underwent DC between January 2023 and December 2024. In each case, bedside transcraniectomy ultrasonography (BTUS) was performed prior to CT imaging, and findings from both modalities were compared. Diagnostic agreement was evaluated using Cohen's kappa coefficient. The sensitivity, specificity, positive predictive value, and negative predictive value were calculated for BTUS in identifying complications, including hematomas, hygroma, hydrocephalus, abscess, edema, and midline shift. RESULTS: BTUS has high diagnostic accuracy compared with CT, with overall sensitivities ranging from 59.4% (edema) to 100% (hematomas) and specificities between 94.2% and 100%. Strong or almost perfect agreement (κ > 0.8) was observed for most complications. The rate of false negatives was lowest for space-occupying lesions and highest for diffuse pathologies, such as edema. Negative predictive values remained above 80% for all major complication types. CONCLUSIONS: BTUS provides a rapid, noninvasive, and readily available tool for the initial detection and monitoring of postcraniectomy complications. While it does not entirely replace CT in complex cases, it holds significant potential as a first-line screening and monitoring modality in neurosurgical intensive care settings. Bedside ultrasonography can significantly reduce reliance on CT scans, particularly in unstable or radiation-sensitive patients. Incorporating routine BTUS into post-DC monitoring protocols could enhance patient safety, expedite diagnosis, and optimize resource utlization in neurocritical care.
引用
- Kwiatkowski A, Sbriglio C, Druszcz A, et al. Diagnostic performance of bedside transcranial ultrasound after decompressive craniectomy: a comparative study with cranial computed tomography. J Neurosurg. 2026. PMID: 42826408. doi:10.3171/2026.4.JNS26111
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。