文献速递功能神经外科

基于CT生成合成MRI定位颅内电极的解剖准确性

Anatomical Localization of Intracranial Electrodes Using Synthetic MRI Generated from Computed Tomography.
PubMed 文献 · Neurosurgery · 2026-08-14

本研究在44例帕金森病丘脑底核脑深部电刺激患者中,评估SynthSR从术前CT生成合成T1 MRI用于电极定位的准确性。与真实MRI-CT融合金标准相比,合成MRI定位的平均径向误差为1.21±0.77 mm,欧氏距离为1.67±0.93 mm,总体STN靶点解剖定位一致率为95.5%。

要点

  • SynthSR合成MRI与金标准定位误差约1-2 mm,接近电极直径。
  • 约10%径向误差>2 mm,1%>4 mm;约30%欧氏距离>2 mm,3%>4 mm。
  • 总体STN靶点定位一致率95.5%,亚区分区一致率81.8%。

核心结论

  • SynthSR从CT生成合成MRI用于DBS电极定位具有初步可行性,但定位差异存在病例间变异。
  • 该纯CT方法可在MRI不可用或禁忌时支持术后评估,有望扩大基于影像的DBS分析可及性。

研究设计与样本

  • 回顾性分析44例接受丘脑底核DBS的帕金森病患者术前CT、术前MRI和术后CT。
  • 患者平均年龄60.7±6.9岁,平均病程10.4±3.9年。
  • 用SynthSR从术前CT生成合成T1,将术后CT分别与合成MRI和真实MRI配准后定位电极并映射至MNI空间。
  • 以真实T1和T1+T2定位为金标准,比较三维欧氏距离、径向距离及STN亚区解剖映射。

主要发现

  • 在MNI空间,SynthSR与T1+T2定位的平均径向误差为1.21±0.77 mm,欧氏距离为1.67±0.93 mm,与电极直径相当。
  • 约10%的径向误差>2 mm,1%>4 mm;约30%的欧氏距离>2 mm,3%>4 mm。
  • 总体STN靶点解剖定位一致率为95.5%,STN亚区分区一致率为81.8%。

临床怎么用

  • 当MRI不可用或禁忌时,可考虑用SynthSR从CT生成合成MRI进行DBS电极术后定位评估。
  • 需注意约10%径向误差>2 mm、约30%欧氏距离>2 mm,亚区分区一致率81.8%,定位差异需结合临床判断。

局限性

  • 定位差异存在病例间变异,部分病例误差较大。
  • 研究为初步可行性评估,样本量44例,结论需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: MRI and computed tomography (CT) are commonly combined to localize intracranial electrodes in deep brain stimulation (DBS). However, when MRI access is limited or unsafe, only CT may be available, which lacks the soft tissue contrast needed for accurate anatomical reference. SynthSR, a deep learning tool that generates synthetic T1-weighted MRI from CT, may address this limitation. We evaluated the accuracy of SynthSR-based localization compared to standard MRI-CT fusion. METHODS: Preoperative CT, preoperative MRI, and postoperative CT scans were analyzed in 44 patients undergoing subthalamic nucleus (STN) DBS for Parkinson's disease (mean age = 60.7 ± 6.9 years; mean disease duration = 10.4 ± 3.9 years). SynthSR generated synthetic T1 scans from preoperative CTs. Post-operative CT was co-registered to synthetic and real MRIs, and electrodes were localized and warped to Montreal Neurological Institute space using either real or synthetic MRI as reference. SynthSR-based localizations were compared to real T1 and T1 + T2 "gold-standard" localizations using 3-dimensional Euclidean and radial distances, as well as anatomical mapping within STN subdivisions. RESULTS: In Montreal Neurological Institute space, the mean radial error between SynthSR- and T1 + T2-based localizations was 1.21 ± 0.77 mm, with a Euclidean distance of 1.67 ± 0.93 mm-comparable to electrode diameter. Roughly 10% of radial errors were >2 mm and 1% were >4 mm. Around 30% of Euclidean distances were >2 mm, and 3% were >4 mm. Anatomical localization concordance was 95.5% for overall STN targeting and 81.8% within STN subdivisions. CONCLUSION: DBS electrode localization using synthetic MRI generated from CT via SynthSR demonstrated preliminary feasibility for DBS electrode localization, although localization differences varied across cases. This CT-only approach may enable postoperative evaluation when MRI is unavailable or contraindicated, supporting broader access to imaging-based DBS analysis as synthetic image generation continues to improve.