文献速递神经肿瘤

低级别胶质瘤质子放疗后的生存、晚期毒性与重返工作能力

Survival, late toxicity and ability to return to work after proton radiotherapy for low-grade gliomas.
PubMed 文献 · J Neurooncol · 2026-07-22

该回顾性分析纳入143例2016 CNS WHO 1–2级胶质瘤术后接受调强质子束放疗(IMPT)的患者,中位随访66.5个月,报告5年OS与PFS及晚期毒性,并分析全职工作维持情况;结果显示照射脑体积(PTV)每增加1 cm³,恢复原全职工作的能力显著降低0.5%。

要点

  • IMPT后5年OS与PFS在全队列分别为78.21%与80.34%。
  • PTV每增加1 cm³,恢复原全职工作能力降低0.5%(OR=0.995,p=0.046)。
  • 晚期CTCAE 3级毒性共4例,包括2例视神经病变。

核心结论

  • 照射脑体积与维持工作能力相关。

研究设计与样本

  • 回顾性分析纳入2016至2021年在本机构术后接受IMPT的2016 CNS WHO 1–2级胶质瘤患者,共143例,数据来自病历与影像记录。

主要发现

  • 中位随访66.5个月,全队列5年OS为78.21%、5年PFS为80.34%。
  • 弥漫性星形细胞瘤IDH突变与肥胖细胞型星形细胞瘤合并组5年OS为76.52%、PFS为65.59%。
  • 少突胶质细胞瘤IDH突变1p19q共缺失组5年OS为85.92%、PFS为86.07%。
  • IMPT后12、36、60个月分别有61例(42.66%)、61例(42.66%)、59例(41.26%)患者维持全职工作。
  • PTV每增加1 cm³,恢复原全职工作的能力显著降低0.5%(OR=0.995,p=0.046)。

关键数值与推荐

  • 平均残留肿瘤体积为61.3 cm³,平均计划靶区体积(PTV)为335.7 cm³。
  • 报告4例CTCAE 3级晚期毒性:2例视神经病变、1例晚期疲乏、1例肌无力。

临床怎么用

  • 制定IMPT计划时应关注照射脑体积,以利于患者维持全职工作能力。
  • 随访中需监测视神经病变等晚期毒性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Level I evidence to inform decisions on radiation modality and chemotherapy regimen choice in adult-type diffuse gliomas CNS WHO grade 2 are awaited. The retrospective analysis was performed to assess overall survival (OS), progression-free survival (PFS) and late toxicity including ability to return to work in 2016 CNS WHO grade 1 and grade 2 gliomas (low-grade gliomas [LGG]) patients treated with intensity modulated proton beam radiotherapy (IMPT). METHODS: Patients with 2016 CNS WHO LGG after surgery, treated with IMPT at our institution from 2016 to 2021 were eligible for this analysis. Data were retrospectively collected from medical and imaging records. RESULTS: 143 patients were identified. Diffuse astrocytoma isocitrate dehydrogenase (IDH) mutant was the predominant phenotype. Median follow-up was 66.5 months. Five-year OS and PFS were 78.21%, 76.52%, 85.92% and 80.34%, 65.59%, 86.07% for the whole cohort, diffuse astrocytoma IDH mutant and gemistocytic astrocytoma combined, and oligodendroglioma IDH mutant 1p19q codeleted respectively. Mean residual tumor volume was 61.3 cm³ and mean planning target volume (PTV) was 335.7 cm³. At 12, 36 and 60 months after IMPT 61 (42.66%), 61 (42.66%) and 59 (41.26%) patients held down in full-time employment. Each additional cubic centimeter of PTV significantly reduced ability to return to the initial full-time work by 0.5% (Odds Ratio [OR] = 0.995, p = 0.046). 4 cases of CTCAE grade 3 late toxicity were reported (2 cases of optic neuropathy, 1 late fatigue, and 1 muscle weakness). CONCLUSIONS: Irradiation brain volume is associated with maintaining ability to work.

来源:J Neurooncol,查看原文。版权归原作者所有。

引用

  1. Wojton-Dziewońska D, Skóra T, Anioł J, et al. Survival, late toxicity and ability to return to work after proton radiotherapy for low-grade gliomas. J Neurooncol. 2026. PMID: 42484755. doi:10.1007/s11060-026-05720-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。