腰椎穿刺开放压力与持续颅内压监测在特发性颅内压增高中的一致性与临床意义
结果显示两者仅中度相关(ρ=0.37-0.51,P≤.014),LP压力较ICPm高10-27 mm Hg,且LP常高估实质颅内压并无法捕捉体位与昼夜变异。
要点
- LP与持续ICPm不可互换,LP系统性高估实质颅内压。
- LP压力较ICPm高10-27 mm Hg,仅中度相关(ρ=0.37-0.51)。
- 低或混合ICP profile患者中LP常显示正常或升高,不一致显著。
核心结论
- LP与持续ICPm不可互换,LP系统性高估实质颅内压且无法捕捉体位与昼夜变异。
主要发现
- LP识别32例(39.5%)压力升高,而ICPm分类为高10例(12.3%)、低18例(22.2%)、混合8例(9.9%)、正常45例(55.6%)。
- LP与ICPm值仅中度相关(ρ=0.37-0.51,P≤.014),LP压力较ICPm高10-27 mm Hg。
- 低或混合ICP profile患者中LP常给出正常或升高读数,不一致显著。
关键数值与推荐
- LP与ICPm相关性ρ=0.37-0.51(P≤.014)。
- LP压力较ICPm高10-27 mm Hg。
临床怎么用
- LP仍可用于初始诊断,但持续ICPm提供更全面生理评估,可能更好指导持续或症状不明确IIH患者的管理。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVES: Lumbar puncture (LP) remains a standard diagnostic tool for assessing intracranial pressure (ICP) in idiopathic intracranial hypertension (IIH), yet it provides only a single static measurement that may not reflect dynamic pressure fluctuations. Although continuous ICP monitoring (ICPm) offers real-time assessment of postural and circadian variability, the relationship between LP and ICPm measurements done after nondiagnostic LP remains unclear. METHODS: We retrospectively reviewed adult patients with IIH at a single center (2016-2023) who underwent ICPm within 9 months of an LP without intervening therapies affecting ICP. Continuous ICPm recordings were analyzed across postures and tilt angles and compared with LP opening pressures using Spearman correlation, Bland-Altman analysis, and categorical concordance of normal, high-, and low-pressure classifications. RESULTS: Eighty-one patients met inclusion criteria (mean age 38.1 ± 11.8 years, 87.7% female, mean body mass index 34.7 ± 8.8 kg/m 2 ). LP identified elevated pressure in 32 (39.5%) patients, while m categorized 10 (12.3%) as high, 18 (22.2%) as low, 8 (9.9%) as mixed, and 45 (55.6%) as normal. LP and ICPm values demonstrated only moderate correlation (ρ = 0.37-0.51, P ≤ .014) with a consistent negative bias, as LP pressures were 10 to 27 mm Hg higher than observed for ICPm. Discordance was notable in patients with low or mixed ICP profiles, in whom LP frequently yielded normal or elevated readings. CONCLUSION: LP and continuous ICPm are not interchangeable, as LP systematically overestimates parenchymal ICP and fails to capture postural and circadian variability. While LP remains useful for initial diagnosis, continuous ICPm provides a more comprehensive physiological assessment and may better guide management in IIH patients with persistent or ambiguous symptoms.
引用
- Maroufi SF, Katkade O, Puppalla P, et al. Lumbar Puncture Opening Pressure and Continuous Intracranial Pressure Monitoring: Concordance and Clinical Implications in Idiopathic Intracranial Hypertension. Neurosurgery. 2026. PMID: 42084378. doi:10.1227/neu.0000000000004068
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。