帽状腱膜下与白质参考电极在立体脑电图中的临床影响与信号质量比较
本研究在14例耐药性癫痫患者中评估帽状腱膜下(SG)电极作为立体脑电图(sEEG)参考的可行性与信号质量,并与白质(WM)和灰质(GM)参考对比。结果显示SG参考安全无不良反应,且具有更高的癫痫发作起始区选择性指数、更低的跨通道相关性和更好的高频功率保留。
要点
- SG参考电极放置安全,无不良反应报告。
- SG参考的SSI高于WM或GM参考。
- SG参考跨通道相关性更低且高频功率保留更多。
核心结论
- 帽状腱膜下电极可作为中立的中线参考,是白质参考的安全替代方案。
- SG参考改善信噪比且不干扰临床调查。
研究设计与样本
- 14例耐药性癫痫患者接受颅内监测并放置SG参考电极。
- 其中4例获取5分钟清醒静息基线记录,比较SG、WM和GM参考的信号。
主要发现
- SG参考的SSI高于WM或GM参考。
- SG参考的跨通道相关性低于WM和GM参考。
- SG参考较WM或GM参考保留更多高频功率。
- 无参与者报告SG电极放置的不良反应。
临床怎么用
- 可考虑使用中线帽状腱膜下电极作为sEEG记录的参考。
- SG参考可能提高信号定位质量且不增加风险。
局限性
- 仅4例参与者用于信号质量对比分析。
- 样本量较小(14例),需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Stereo-electroencephalography (sEEG) is a common method for clinical epilepsy monitoring and provides unique opportunities for intracranial research in humans. Optimal selection of reference electrodes is essential for obtaining high-quality localizable data. White matter (WM) electrode contacts are commonly used as references; however, this reference scheme presents several limitations that may influence the data, including a limited selection of electrodes in the WM, nonneutral activity in the WM, and a laterality bias. Here, the authors detail the use of a midline subgaleal (SG) electrode as an alternative reference for sEEG recordings. METHODS: An SG reference was used for 14 patients with drug-resistant epilepsy undergoing intracranial monitoring. Following the placement of sEEG electrodes, one 8-contact sEEG electrode (n = 2) or 4-contact strip electrode (n = 12) was placed in the SG space at the parietal midline. In a subset of 4 participants, we obtained awake, resting baseline recordings (5-minute duration) using different references, allowing us to compare signals recorded with an SG, WM, and gray matter (GM) reference. The authors compared the number of interictal spikes (IISs) detected by measuring the seizure onset zone selectivity index (SSI), cross-channel correlations, and power spectral density properties across these baseline recordings. RESULTS: No adverse effect of the SG electrode placement was reported in any participant. Recordings using an SG reference have a higher SSI compared with a WM or GM reference. Neural signals obtained with an SG reference have lower cross-channel correlations compared with the other two references and preserve more power at higher frequencies than a WM or GM reference. CONCLUSIONS: Extracranial placement of an SG electrode allows for a neutral midline reference. The authors' findings demonstrate that an SG reference is a safe alternative to the standard WM reference, improving the signal-to-noise ratio and not interfering with the clinical investigation.
引用
- Devara D, Jourahmad Z, Paulo DL, et al. Subgaleal versus white matter reference for stereo-electroencephalography recordings: comparison of clinical impact and signal quality. J Neurosurg. 2026. PMID: 42066368. doi:10.3171/2025.12.JNS251675
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。