无框架无基准点脑深部电刺激手术:178例患者回顾性比较
该回顾性研究比较了无框架(FL)、无框架无基准点(FLFL)和 poised cannula(PC)脑深部电刺激(DBS)的舒适度与 accuracy。178例患者中,FLFL与PC的径向误差无显著差异(1.2±0.7 mm vs 1.1±0.5 mm,p=0.055),并发症率相近,患者舒适度评分相似。结论认为FLFL和PC是安全舒适的替代方案。
要点
- FLFL与PC的径向误差无显著差异(1.2±0.7 mm vs 1.1±0.5 mm,p=0.055)。
- FLFL与PC的颅内事件并发症率分别为0.0% vs 2.2%,硬件移除率3.3% vs 3.2%。
- 三组患者舒适度评分相似(FL 7.6±0.7,FLFL 8.1±0.7,PC 7.7±0.7,两两p>0.3)。
核心结论
- FLFL和PC手术是F和FL-DBS手术的安全且舒适的替代方案。
研究设计与样本
- 回顾性研究,纳入2018年1月至2023年8月在本机构接受DBS的178例患者,期间从FL过渡到FLFL再至PC。
主要发现
- FLFL组92例(136根电极)与PC组93例(134根电极)的平均径向误差分别为1.2±0.7 mm和1.1±0.5 mm,Mann-Whitney U检验p=0.055,r=0.14。
- 误差>2.5 mm的病例比例FLFL为3.7%,PC为0.7%。
- 并发症率FLFL vs PC:颅内事件0.0% vs 2.2%,硬件移除3.3% vs 3.2%,电极翻修0.0% vs 0.0%。
- 160名调查应答者(FL 50例,FLFL 48例,PC 62例)的平均舒适度相似(7.6±0.7,8.1±0.7,7.7±0.7;所有两两Mann-Whitney p>0.3)。
- 约三分之一的PC患者对手术无记忆但仍报告非常舒适。
临床怎么用
- FLFL和PC手术可作为F和FL-DBS的安全舒适替代方案,但需注意PC组颅内事件率略高(2.2%)。
局限性
- 未来研究需在计算总体患者舒适度前控制麻醉的遗忘效应。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Deep brain stimulation (DBS) is often performed on awake patients using frame-based neuronavigation. Patients have associated the stereotactic frame with pain. We assessed patient comfort and accuracy of alternative procedures including frameless (FL), frameless fiducial-less (FLFL), and poised cannula (PC) DBS. METHODS: Medical records were reviewed for 178 patients who underwent DBS between Jan. 2018 and Aug. 2023 at our institution. We transitioned from FL- to FLFL-DBS and then to PC-DBS during this period. Surveys were sent to all patients. Nonparametric tests were used for non-normally distributed data. RESULTS: Medical records were reviewed for 92 FLFL patients (136 leads) and 93 PC patients (134 leads). The mean radial error was 1.2 ± 0.7 mm (FLFL) vs 1.1 ± 0.5 mm (PC); this difference did not reach significance on Mann-Whitney U testing (p = 0.055, r = 0.14). Cases with > 2.5 mm error were 3.7% (FLFL) and 0.7% (PC). Complication rates for FLFL vs PC were 0.0% vs 2.2% (intracranial events), 3.3% vs 3.2% (hardware removal), and 0.0% vs 0.0% (lead revisions). Of 160 survey respondents (50 FL, 48 FLFL, 62 PC), mean comfort was similar (7.6 ± 0.7, 8.1 ± 0.7, 7.7 ± 0.7; all pairwise Mann-Whitney p > 0.3). Approximately one third of PC patients had no memory of the procedure but still reported being very comfortable. CONCLUSIONS: FLFL and PC procedures are safe and comfortable alternatives to F- and FL-DBS procedures. Future studies should control for amnestic effects of anesthesia before calculating overall patient comfort.
引用
- Hockman JT, Ganev Y, Sankhyan M, et al. Frameless and Fiducial-Less Deep Brain Stimulation Surgeries: A Retrospective Comparison of 178 Patients. World Neurosurg. 2026. PMID: 42176734. doi:10.1016/j.wneu.2026.125066
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。