1H-MRS检测成人弥漫性胶质瘤2HG的诊断准确性
本研究评估短回波(TE 30 ms)、中间回波(TE 97 ms)和MEGA-PRESS三种1H-MRS策略检测2-羟基戊二酸(2HG)以无创判定IDH突变状态的诊断准确性,纳入152例成人弥漫性胶质瘤患者(84例IDH突变型,68例IDH野生型)。结果显示短回波和中间回波PRESS序列技术可靠性更高,联合应用时灵敏度达100%、特异度85.7%、总体准确率93.7%。
要点
- 中间回波(TE 97 ms)特异度100%、灵敏度51.2%,短回波(TE 30 ms)特异度97%、灵敏度88.9%。
- MEGA-PRESS特异度86.7%、灵敏度72.2%,但非诊断率高达17.5%。
- 联合三种MRS方法灵敏度100%、特异度85.7%、总体准确率93.7%。
核心结论
- 常规PRESS序列(TE 30 ms和TE 97 ms)在常规临床检测2HG方面优于MEGA-PRESS,因其技术可靠性更高。
- 优化的常规PRESS协议可作为识别胶质瘤基因型和预测肿瘤表型的稳健、高准确、无创的术前工具。
研究设计与样本
- 纳入152例成人弥漫性胶质瘤患者(84例IDH突变型,68例IDH野生型),术前行3T MRI包括标准形态学序列和1H-MRS采集。
- 评估三种1H-MRS策略:短回波(TE 30 ms)、中间回波(TE 97 ms)和MEGA-PRESS,分析2HG峰存在情况。
- 分别分析每种方法的诊断性能,并对接受全部三种序列的子组患者进行联合分析。
主要发现
- 中间回波(TE 97 ms)方法特异度100%、灵敏度51.2%。
- 短回波(TE 30 ms)序列特异度97%、灵敏度88.9%。
- MEGA-PRESS方法特异度86.7%、灵敏度72.2%,但非诊断率高达17.5%,易受伪影影响。
- 联合应用时,MRS方法检测2HG的灵敏度100%、特异度85.7%、总体准确率93.7%。
临床怎么用
- 常规临床可优先采用短回波(TE 30 ms)和中间回波(TE 97 ms)PRESS序列检测2HG,以无创预测IDH突变状态。
- MEGA-PRESS因非诊断率较高,不作为常规首选。
- 联合应用PRESS序列可提高诊断准确性,辅助术前基因分型。
局限性
- MEGA-PRESS方法非诊断率高达17.5%,受伪影影响较大。
- 联合分析仅基于接受全部三种序列的子组患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the diagnostic accuracy of three proton magnetic resonance spectroscopy (1H-MRS) strategies-short echo (TE 30 ms), intermediate echo (TE 97 ms), and MEGA-PRESS-for detecting the oncometabolite 2-hydroxyglutarate (2HG) to non-invasively determine isocitrate dehydrogenase (IDH) mutation status in adult-type diffuse gliomas. METHODS: A cohort of 152 patients with adult-type diffuse gliomas (84 IDH-mutant, 68 IDH-wild-type) underwent preoperative 3T MRI incorporating standard morphological sequences and 1H-MRS acquisitions. Spectra were evaluated to assess the presence of a 2HG peak. Diagnostic performance was analysed independently for each method and collectively for a subgroup of patients receiving all three sequences. RESULTS: The intermediate echo (TE 97 ms) method demonstrated 100% specificity and 51.2% sensitivity, while the short echo (TE 30 ms) sequence achieved 97% specificity and 88.9% sensitivity. The MEGA-PRESS method yielded 86.7% specificity and 72.2% sensitivity but was limited by a high non-diagnostic rate (17.5%) due to artifact susceptibility. When combined, the spectroscopy methods achieved 100% sensitivity, 85.7% specificity, and 93.7% overall accuracy in detecting 2HG. CONCLUSION: Conventional PRESS sequences (TE 30 ms and TE 97 ms) outperform MEGA-PRESS for the routine clinical detection of 2HG due to higher technical reliability. An optimized conventional PRESS protocol offers a robust, highly accurate, and non-invasive preoperative tool for identifying glioma genotypes and predicting tumour phenotypes.
引用
- Hebda A, Wawrzyniak P, Heinze S, et al. Diagnostic accuracy of 1H-MRS in detecting the oncometabolite 2-hydroxyglutarate (2HG) in adult-type diffuse gliomas. J Neurooncol. 2026. PMID: 42133138. doi:10.1007/s11060-026-05600-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。