相对皮层下萎缩指数对特发性正常压力脑积水的诊断准确性
本研究回顾性分析78例接受脑室腹腔分流术的特发性正常压力脑积水(iNPH)患者,并与健康对照及可能iNPH患者比较,评估相对皮层下萎缩(RSCA)指数的诊断准确性。RSCA指数在iNPH患者与健康对照及可能iNPH患者间均有显著差异(P < .001),AUC为0.959(95% CI,0.91-1.00), cutoff值0.62(P < .001)时敏感度92.3%、特异度94.6%,术后值较术前显著降低(P < .001),评分者间信度优秀(ICC=0.997;95% CI:0.996-0.998;P < .001)。结论认为RSCA指数对iNPH具有高诊断准确性,术后显著变化支持其作为诊断和手术随访的可靠影像生物标志物。
要点
- RSCA指数在iNPH与健康对照及可能iNPH间差异显著(P < .001)。
- AUC 0.959,cutoff 0.62时敏感度92.3%、特异度94.6%。
- 术后RSCA值较术前显著降低(P < .001),或可用于手术随访。
核心结论
- RSCA指数对iNPH诊断准确性高,术后显著变化支持其作为诊断和手术随访的影像生物标志物。
研究设计与样本
- 回顾性分析78例接受脑室腹腔分流术的iNPH患者,并与健康对照及可能iNPH患者比较。
- 诊断依据日本iNPH管理指南,包括认知、平衡和步态系列评估及预定住院期间的脑脊液分流试验。
- 术前及不同随访时间用FLAIR MRI由2名神经外科医生独立测量RSCA指数和经室管膜水肿最大线性延伸。
- 独立验证团队进行数据验证。
主要发现
- iNPH患者与健康对照间RSCA指数差异显著(P < .001)。
- iNPH患者与可能iNPH患者间RSCA指数差异显著(P < .001)。
- ROC曲线下面积为0.959(95% CI,0.91-1.00)。
- cutoff值0.62(P < .001)区分患者与对照的敏感度92.3%、特异度94.6%。
- 术后RSCA值较术前显著降低(P < .001)。
关键数值与推荐
- RSCA指数cutoff值0.62(P < .001),敏感度92.3%、特异度94.6%。
- AUC 0.959(95% CI,0.91-1.00)。
- ICC=0.997(95% CI:0.996-0.998;P < .001)。
临床怎么用
- RSCA指数可作为iNPH诊断的可靠影像生物标志物,辅助鉴别iNPH与健康对照及可能iNPH。
- 术后RSCA指数显著降低,提示其可用于手术随访评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVES: In neurosurgical practice, idiopathic normal pressure hydrocephalus (iNPH) presents notable diagnostic and therapeutic challenges. This study aimed to evaluate the diagnostic accuracy of the relative subcortical atrophy (RSCA) index and to investigate its potential role in assessing surgical response. METHODS: A retrospective analysis was conducted on 78 patients who underwent ventriculoperitoneal shunt for iNPH and compared with healthy controls and patients with possible iNPH. Diagnosis was established in accordance with the Japanese Guidelines for Management of iNPH, including serial assessments of cognition, balance, and gait, as well as cerebrospinal fluid diversion during a predetermined hospitalization. Neurocognitive, balance, and gait performance were assessed before and after the cerebrospinal fluid tap test. Clinical outcomes were evaluated at 1, 6, and 18 months postoperatively. The RSCA index and the maximum linear extension of transependymal edema were independently measured by 2 neurosurgeons using fluid-attenuated inversion-recovery MRI preoperatively and at different follow-up times. An independent validation team was recruited to perform the data validation process. RESULTS: A significant difference was observed in the RSCA index between patients with iNPH and healthy controls (P < .001) as well as between possible iNPH patients (P < .001). The area under the receiver operating characteristic curve was 0.959 (95% CI, 0.91-1.00). A cutoff value of 0.62 (P < .001) yielded high sensitivity (92.3%) and specificity (94.6%) in discriminating patients from controls. Postoperative values demonstrated a significant reduction compared with preoperative measurements (P < .001). Inter-rater reliability was excellent (intraclass correlation coefficient = 0.997; 95% CI: 0.996-0.998; P < .001). CONCLUSION: The RSCA index demonstrated high diagnostic accuracy for iNPH and showed significant postoperative variation, supporting its potential utility as a reliable radiological biomarker in both diagnosis and surgical follow-up.
引用
- Bruzzaniti P, Pennisi G, Burattini B, et al. Diagnostic Accuracy of the Relative Subcortical Atrophy Index in Idiopathic Normal Pressure Hydrocephalus. Neurosurgery. 2026. PMID: 41940655. doi:10.1227/neu.0000000000004018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。