标准化T2WI强度比值预测垂体大腺瘤质地
本研究基于单中心2011-2024年前瞻性数据库,纳入189例垂体大腺瘤患者,评估标准化肿瘤与小脑T2WI强度比值(TCTI)对肿瘤质地的预测价值。结果显示TCTI比值越低肿瘤越硬,最大信号强度测量预测硬肿瘤的AUC为0.877,TCTI截断值1.682预测硬肿瘤的敏感度80.6%、特异度85.7%。
要点
- TCTI比值可用于术前无创预测垂体大腺瘤质地。
- TCTI比值越低,肿瘤质地越硬。
- 最大信号强度测量预测硬肿瘤的AUC为0.877。
核心结论
- T2WI TCTI比值可预测垂体腺瘤质地,比值越高肿瘤越软。
研究设计与样本
- 单中心前瞻性维护数据库回顾性分析,纳入2011-2024年接受手术的189例垂体大腺瘤患者,要求肿瘤至少一维直径≥20mm、术中采用经验证的质地分级且术前有MRI。
主要发现
- 质地分级1+2级77例(40.7%)、3级76例(40.2%)、4+5级36例(19%)。
- 平均T2WI测量:4+5级TCTI比值1.48±0.24,低于3级1.77±0.44(p<0.001)和1+2级2.16±1.10(p=0.001)。
- 最大T2WI测量:4+5级TCTI比值1.50±0.24,低于3级1.79±0.45(p<0.001)和1+2级2.15±0.81(p<0.001)。
- ADC值与肿瘤质地无关联。
- ROC分析比较软(1+2级)与硬(4+5级)肿瘤,最大信号强度测量的AUC为0.877。
关键数值与推荐
- TCTI比值截断值1.682预测硬肿瘤(4+5级)对比其他所有级别,在测试集中敏感度80.6%、特异度85.7%。
临床怎么用
- 术前使用TCTI比值可能改善患者选择和结果预测,并指导切除技术。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The physical consistency of pituitary adenomas (PAs) is highly variable, ranging from soft/cystic to firm/calcified. The association between PA consistency and surgical/endocrinological outcomes has been well established, with firm tumors demonstrating poorer outcomes and higher complication rates. However, to date, no reliable means to determine PA consistency preoperatively exist, although T2- and diffusion-weighted imaging show early promise. As such, this study aimed to quantitatively analyze the value of normalized T2-weighted imaging (T2WI) and diffusion-weighted imaging ratios in the preoperative prediction of PA consistency. METHODS: The authors reviewed a prospectively maintained database of all patients undergoing PA resection at a single institution between 2011 and 2024. Inclusion criteria included the following: 1) a PA with a minimum diameter ≥ 20 mm in at least one dimension; 2) a consistency grade assigned at the time of surgery using a previously validated grading scale; and 3) preoperative MRI performed prior to surgery. Normalized tumor to cerebellar T2-weighted imaging intensity (TCTI) ratios were calculated using 10-mm2 regions of interest. Data were analyzed using Kruskal-Wallis tests, multivariable ordinal logistic regression models, and receiver operating characteristic (ROC) curve analyses with 4-fold cross-validation. RESULTS: A total of 189 patients (mean age 55.4 years, 49.2% female) were included, of whom 77 (40.7%) had PAs with a consistency grade of 1+2, 76 with a consistency grade of 3 (40.2%), and 36 (19%) with a consistency grade of 4+5. When using mean T2WI intensity measurements, TCTI ratios were lower for grade 4+5 tumors (1.48 ± 0.24, p < 0.001) than for grade 3 tumors (1.77 ± 0.44) and grade 1+2 tumors (2.16 ± 1.10, p = 0.001). When using maximum T2WI measurements, TCTI ratios were also lower for grade 4+5 tumors (1.50 ± 0.24, p < 0.001) compared with grade 3 tumors (1.79 ± 0.45), and grade 1+2 tumors (2.15 ± 0.81, p < 0.001). No association between apparent diffusion coefficient values and tumor consistency was observed. In the ROC analysis, comparing soft (grade 1+2) with firm (grade 4+5) tumors, an area under the curve of 0.877 was observed when using maximum signal intensity measurements within the ROI. A TCTI ratio cutoff of 1.682 was associated with a sensitivity of 80.6% and specificity of 85.7% in predicting firm tumors (grade 4+5) versus all other grades in the test dataset. CONCLUSIONS: The T2WI TCTI ratio is predictive of PA consistency where higher ratios are associated with softer tumors. Preoperative prediction of PA consistency using the TCTI ratio might improve patient selection and outcome predication, and guide the excision technique.
引用
- Shah I, Gomez D, Cote DJ, et al. Utility of standardized T2-weighted MRI intensity ratio for prediction of pituitary macroadenoma consistency. J Neurosurg. 2026. PMID: 41569688. doi:10.3171/2025.8.JNS25387
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。