半坐位显微手术夹闭破裂后颅窝动脉瘤的安全性与疗效
本研究回顾性分析了1990至2023年间39例在半坐位下接受显微手术夹闭的破裂后循环动脉瘤患者。结果显示动脉瘤完全闭塞率达92%,手术死亡率为0%,6个月时84%的存活患者格拉斯哥结局量表评分大于3分。尽管经食管超声监测发现20%的患者存在静脉空气栓塞,但均未导致手术中止或严重并发症。
要点
- 半坐位夹闭破裂后颅窝动脉瘤完全闭塞率92%,手术死亡率0%。
- 经食管超声监测静脉空气栓塞发生率20%,但无严重并发症。
- 6个月时84%存活患者格拉斯哥结局量表评分大于3分。
核心结论
- 在适当监测下,半坐位显微手术夹闭破裂后颅窝动脉瘤安全有效。
- 与麻醉团队的密切合作对确保患者安全至关重要。
- 研究结果支持半坐位在后颅窝动脉瘤手术中的持续应用价值。
研究设计与样本
- 回顾性研究,纳入1990至2023年间连续39例在半坐位下接受显微手术夹闭的破裂后循环动脉瘤患者。
- 收集数据包括临床表现、手术技术、术中及术后并发症,以及出院时和6个月时的格拉斯哥结局量表评分。
主要发现
- 动脉瘤完全闭塞率为92%(36/39)。
- 最常见动脉瘤位置为小脑后下动脉(79%)。
- 术中破裂发生率为8%(3/39),手术导致的新发神经功能缺损为13%(5/39)。
- 经食管超声监测的患者中静脉空气栓塞发生率为20%(3/15),但无病例需中止手术或导致严重并发症。
- 手术死亡率为0%,6个月时84%(21/25)的存活患者格拉斯哥结局量表评分大于3分。
临床怎么用
- 对于破裂后颅窝动脉瘤,可考虑在半坐位下进行显微手术夹闭,但需配备适当监测。
- 应密切与麻醉团队协作以确保患者安全。
- 经食管超声可用于监测静脉空气栓塞,但发生率较高且通常不导致严重后果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Posterior fossa aneurysms, especially ruptured ones, are challenging to treat due to their deep location, complex anatomy, and proximity to the brainstem, and lower cranial nerves. The semi-sitting position, though historically controversial due to concerns over venous air embolism, may offer distinct advantages. The aim of this study was to evaluate the safety and efficacy of the semi-sitting position for the clipping of ruptured posterior fossa aneurysms. METHODS: We retrospectively reviewed 39 consecutive patients with ruptured posterior circulation aneurysms treated with microsurgical clipping in the semi-sitting position between 1990 and 2023. Data included clinical presentation, surgical technique, intraoperative and postoperative complications, and functional outcomes measured by the Glasgow Outcome Scale at discharge and at 6 months. RESULTS: Complete aneurysm occlusion was achieved in 92% (36/39). The most common aneurysm location was the posterior inferior cerebellar artery (79%). Intraoperative rupture occurred in 8% (3/39), and new neurological deficits attributable to surgery were seen in 13% (5/39). Venous air embolism was detected in 20% (3/15) of patients monitored with transesophageal echocardiography, though no cases required abortion of the procedure or resulted in serious complications. Surgical mortality was 0%, and 84% (21/25) of surviving patients achieved a Glasgow Outcome Scale >3 at 6 months. CONCLUSION: Microsurgical clipping of ruptured posterior fossa aneurysms in the semi-sitting position is safe and effective when performed with appropriate monitoring. Close collaboration with the anesthesiology team is essential to ensure patient safety. Our findings reinforce the continued relevance of the semi-sitting position in posterior fossa aneurysm surgery.
引用
- Kranawetter B, Abboud T, Popov Y, et al. Microsurgical Clipping of Ruptured Posterior Fossa Aneurysms in the Semi-Sitting Position. World Neurosurg. 2026. PMID: 41579950. doi:10.1016/j.wneu.2026.124827
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。