概率纤维束示踪预测DBS「最佳靶点」的精度:注意误差

How accurate is probabilistic tractography when used to predict the "sweet spot" in deep brain stimulation? Mind the gap!
PubMed 文献 · Acta Neurochir (Wien) · 2025-12-01

该研究在40例接受双侧DBS手术的PD和ET患者中,使用FSL 6.0.3对齿状核-红核-丘脑束交叉与非交叉部分进行概率纤维束示踪,并用LeadDBS重建电极,评估二值化阈值、手动与自动距离测量及MNI标准化对测量距离的影响。结果显示不同阈值导致测量距离非线性不可预测变化达1.72±1.49 mm,手动测量平均误差0.91±1.36 mm(最大14.9 mm),标准化平均误差0.82±0.50 mm(最大2.34 mm),最大误差可达数毫米,可能显著影响DBS临床靶点选择。

要点

  • 纤维束二值化阈值选择可致测量距离变化达1.72±1.49 mm,且呈非线性不可预测。
  • 手动测量较自动测量平均误差0.91±1.36 mm,最大可达14.9 mm。
  • MNI标准化较原生空间测量平均误差0.82±0.50 mm,最大2.34 mm。

核心结论

  • 概率纤维束示踪用于DBS靶点预测时,测量最大误差可达数毫米,可能显著影响临床靶点选择。

研究设计与样本

  • 研究纳入40例接受双侧DBS手术的PD和ET患者,使用FSL 6.0.3进行c-/nd-DRTT概率纤维束示踪,并用LeadDBS重建电极。

主要发现

  • 不同二值化阈值导致测量距离非线性不可预测变化,达1.72±1.49 mm(均值±标准差)。
  • 手动测量较自动测量平均误差0.91±1.36 mm,最大14.9 mm。
  • MNI标准化较原生空间测量平均误差0.82±0.50 mm,最大2.34 mm。

临床怎么用

  • 研究者应认识到纤维束示踪各处理步骤的误差,并为具体研究制定个体化标准。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Tractography has been used in various studies with respect to the improvement of patient-specific DBS targeting. Nevertheless, methodological influences of the chosen parameters and associated errors are often neglected. The aim of this study was to estimate concrete errors associated with specific image processing steps when using measurements of distances to specific subcortical fiber tracts to predict optimal stimulation sites for DBS targeting. METHOD: Probabilistic tractography of the crossing and non-decussating part of the dentato-rubro-thalamic-tract (c-/ nd-DRTT) was performed using FSL 6.0.3 in 40 PD- and ET-patients having received bilateral DBS surgery. DBS-electrodes were reconstructed using LeadDBS. The influence of (1) the choice of threshold for binarization of fiber tracts, (2) manual measurements compared to measurements using automized distance maps and (3) normalization into the MNI standard space on measured distances were investigated. RESULTS: Different thresholds for binarization resulted in non-linear and unpredictable variations of measured distances up to 1.72 ± 1.49 mm (mean value ± standard deviation). Manual measurements on the axial slice of the electrode contact showed a mean error of 0.91 ± 1.36 mm (maximum 14.9 mm) compared to automated measurements. Regarding normalization, a mean error of 0.82 ± 0.50 mm (maximum 2.34 mm) was found compared to measurements in native space. CONCLUSION: Measured maximum errors reach up to several millimeters, which might have significant impact on clinical targeting in DBS. Researchers should be aware of these errors and define individual standards for specific studies.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。