文献速递脑血管病外科神经重症

CT血管成像三维容积渲染对蛛网膜下腔出血动脉瘤检测的价值:与DSA对比

Comparison of the Diagnostic Utility of Computed Tomography Angiography Head With and Without 3-Dimensional Volume-Rendered Images for Aneurysm Detection in Subarachnoid Hemorrhage Patients Versus Digital Subtraction Angiography.
PubMed 文献 · Neurosurgery · 2025-08-28

该回顾性研究纳入200例自发性蛛网膜下腔出血患者,以DSA为参考标准,比较64排CTA加与不加三维容积渲染(3DVR)对颅内动脉瘤的检测效能。CTA-3DVR检出140个动脉瘤中的135个(96.4%),CTA+3DVR检出136个(97.1%),3DVR仅多检出1个远端A3动脉瘤,未显著提高检出率,但可能有助于急诊动脉瘤形态评估。

要点

  • CTA+3DVR较CTA-3DVR仅多检出1个3mm左侧A3段动脉瘤,检出率从96.4%升至97.1%。
  • 所有漏诊动脉瘤均测量为2-4mm,4个漏诊中3个伴多发动脉瘤。
  • 加与不加3DVR均无假阳性,3DVR可能用于急诊动脉瘤形态描述。

核心结论

  • CTA+3DVR较CTA-3DVR仅多检出1个远端A3动脉瘤,3DVR似乎并未实质性提高动脉瘤检出率,但可能有助于急诊环境下动脉瘤形态学描述。

研究设计与样本

  • 回顾性分析2013至2020年因自发性蛛网膜下腔出血(不限部位)行64排CTA及后续DSA的患者,以DSA(几乎所有采用3D旋转血管造影)为参考标准。
  • 共纳入200例患者,由两名对DSA结果不知情的神经放射科医生分别独立阅片,先评估无3DVR的CTA源图像和最大密度投影图像(CTA-3DVR),随后立即评估3DVR图像(CTA+3DVR),分歧经共识复核解决。
  • 动脉瘤大小在DSA上测量。

主要发现

  • DSA在114例患者中检出140个动脉瘤。
  • CTA-3DVR检出140个动脉瘤中的135个(96.4%),CTA+3DVR检出136个(97.1%)。
  • 所有漏诊动脉瘤均测量为2-4mm;4个漏诊动脉瘤中3个伴多发动脉瘤,1个为单发2mm M3段动脉瘤。
  • CTA+3DVR额外检出的1个动脉瘤为3mm左侧A3段动脉瘤。
  • 加与不加3DVR均无假阳性。

临床怎么用

  • 在蛛网膜下腔出血急诊评估中,不加3DVR的64排CTA已能检出绝大多数动脉瘤,3DVR并非检出所必需。
  • 3DVR可能有助于急诊环境下描述动脉瘤形态,但不应期望其显著提高小动脉瘤(2-4mm)的检出率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: Generating computed tomography (CT) angiography (CTA) 3-dimensional (3D) volume-rendered (3DVR) images can be time consuming without specialized technical staff or artificial intelligence solutions. However, their role in aneurysm detection in patients with subarachnoid hemorrhage is not known. Our aim was to assess the diagnostic utility of 64-detector row CTA with 3DVR (CTA+3DVR) vs without 3DVR (CTA-3DVR) in intracranial aneurysm detection. METHODS: A retrospective analysis of patients presenting with spontaneous subarachnoid hemorrhage (regardless of location) who underwent 64-detector row CTA and subsequent digital subtraction angiography (DSA) between 2013 and 2020 was performed. DSA was the reference standard. Almost all DSAs were performed with 3D rotational angiography. Two neuroradiologists blinded to the DSA results separately reviewed CTA source and maximum intensity projection images without 3DVR images (CTA-3DVR) and then immediately followed by the 3DVR images (CTA + 3DVR). Disagreements were resolved by consensus review. Aneurysm size was measured on DSA. RESULTS: In total, 200 patients were included in the study. 140 aneurysms in 114 patients were detected on DSA. CTA-3DVR detected 135 of 140 aneurysms (96.4%), and CTA+3DVR detected 136 of 140 aneurysms (97.1%). All missed aneurysms measured 2-4 mm. Three of four missed aneurysms were associated with multiple aneurysms, and 1 was a singly occurring, 2-mm M3 segment aneurysm. The 1 additional aneurysm detected by CTA + 3DVR was a 3-mm left A3 segment aneurysm. No false positives occurred with or without 3DVR. CONCLUSION: CTA+3DVR detected 1 additional distal A3 aneurysm vs CTA-VR. 3DVR does not seem to substantially improve the detection of aneurysms but may be useful in the emergent setting for aneurysm morphology characterization.

来源:Neurosurgery,查看原文。版权归原作者所有。

引用

  1. Chang YM, Abdi S, Purohit S, et al. Comparison of the Diagnostic Utility of Computed Tomography Angiography Head With and Without 3-Dimensional Volume-Rendered Images for Aneurysm Detection in Subarachnoid Hemorrhage Patients Versus Digital Subtraction Angiography. Neurosurgery. 2025. PMID: 40874770. doi:10.1227/neu.0000000000003708

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。