文献速递神经肿瘤

基于物理生成人工智能的3T人脑胶质瘤超分辨钠MRI

Super-resolution sodium MRI of human gliomas at 3T using physics-based generative artificial intelligence.
PubMed 文献 · J Neurooncol · 2025-06-03

合成钠图像信噪比显著提高(18.20±7.04对23.83±9.33,P=0.0079),与原生钠测量一致,且与NHE1表达相关性优于原生图像。

要点

  • ATHENA可在3T生成高分辨率合成钠MRI,信噪比显著优于原生钠成像。
  • 合成钠信号与增强区、T2高信号区及坏死区原生测量高度线性相关。
  • 合成钠信号与活检NHE1表达相关性优于原生钠,或可无创反映钠稳态。

核心结论

  • ATHENA可在3T生成高分辨率合成钠MRI,保留原生钠信息,并使脑肿瘤多核成像在临床上可行。
  • 合成钠信号与组织NHE1表达显著相关,有望作为脑肿瘤钠稳态的无创标志物。

研究设计与样本

  • 模型训练采用1,390例疑似脑肿瘤患者的4,573次质子MRI扫描。
  • 验证纳入20例胶质瘤患者的钠与质子MRI数据集。

主要发现

  • 合成钠图像信噪比显著提高:原生18.20±7.04,合成23.83±9.33,P=0.0079。
  • 合成钠值与原生测量一致(P=0.2058)。
  • 肿瘤强化区R2=0.7565(P=0.0005),T2高信号区R2=0.7325(P<0.0001),坏死区R2=0.7678(P<0.0001)。
  • 合成钠与NHE1表达相关性(ρ=0.3269,P<0.0001)优于原生钠(ρ=0.1732,P=0.0276)。
  • NHE1表达升高样本的钠信号更高(P<0.0001)。

临床怎么用

  • 3T下即可获得高分辨率合成钠图像,无需额外高场设备即可开展脑肿瘤多核成像。
  • 合成钠信号或可作为反映肿瘤钠稳态与NHE1表达的无创影像标志物供临床参考。

局限性

  • 研究为单中心影像与免疫组化对照,尚未报告临床结局相关数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Sodium neuroimaging provides unique insights into the cellular and metabolic properties of brain tumors. However, at 3T, sodium neuroimaging MRI's low signal-to-noise ratio (SNR) and resolution discourages routine clinical use. We evaluated the recently developed Anatomically constrained GAN using physics-based synthetic MRI artifacts" (ATHENA) for high-resolution sodium neuroimaging of brain tumors at 3T. We hypothesized the model would improve the image quality while preserving the inherent sodium information. METHODS: 4,573 proton MRI scans from 1,390 suspected brain tumor patients were used for training. Sodium and proton MRI datasets from Twenty glioma patients were collected for validation. Twenty-four image-guided biopsies from seven patients were available for sodium-proton exchanger (NHE1) expression evaluation on immunohistochemistry. High-resolution synthetic sodium images were generated using the ATHENA model, then compared to native sodium MRI and NHE1 protein expression from image-guided biopsy samples. RESULTS: The ATHENA produced synthetic-sodium MR with significantly improved SNR (native SNR 18.20 ± 7.04; synthetic SNR 23.83 ± 9.33, P = 0.0079). The synthetic-sodium values were consistent with the native measurements (P = 0.2058), with a strong linear correlation within contrast-enhancing areas of the tumor (R2 = 0.7565, P = 0.0005), T2-hyperintense (R2 = 0.7325, P < 0.0001), and necrotic areas (R2 = 0.7678, P < 0.0001). The synthetic-sodium MR and the relative NHE1 expression from image-guided biopsies were better correlated for the synthetic (ρ = 0.3269, P < 0.0001) than the native (ρ = 0.1732, P = 0.0276) with higher sodium signal in samples expressing elevated NHE1 (P < 0.0001). CONCLUSION: ATHENA generates high-resolution synthetic-sodium MRI at 3T, enabling clinically attainable multinuclear imaging for brain tumors that retain the inherent information from the native sodium. The resulting synthetic sodium significantly correlates with tissue expression, potentially supporting its utility as a non-invasive marker of underlying sodium homeostasis in brain tumors.

来源:J Neurooncol,查看原文。版权归原作者所有。

引用

  1. Raymond C, Yao J, Lopez Kolkovsky AL, et al. Super-resolution sodium MRI of human gliomas at 3T using physics-based generative artificial intelligence. J Neurooncol. 2025. PMID: 40459830. doi:10.1007/s11060-025-05094-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。