动脉自旋标记评估脑动静脉畸形放射外科治疗后巢内闭塞的前瞻性研究
该前瞻性单中心研究纳入50例接受放射外科治疗的脑动静脉畸形患者,以DSA为金标准,评估标准化MRI方案(含ASL)对巢内闭塞的判断价值。结果显示MRI方案检测残留巢的敏感度为100/100%、特异度为86/79%,观察者间一致性极佳(κ=0.92,0.81-1.00),ASL在所有MRI序列中敏感度最高,提示含ASL的MRI有望替代有创DSA。
要点
- 含ASL的标准化MRI方案检测残留巢敏感度达100/100%,特异度86/79%。
- ASL在所用MRI序列中敏感度最高,3例中为唯一正确显示残留巢的序列。
- 观察者间一致性极佳,κ=0.92(0.81-1.00)。
核心结论
- 含ASL的MRI评估巢内闭塞对残留巢检测高度敏感,有潜力替代有创DSA用于放射外科治疗后的脑AVM患者。
研究设计与样本
- 前瞻性单中心研究,纳入50例放射外科治疗的脑AVM,行标准化MRI方案(含ASL)后3天内行DSA作为参考标准,并由第二位观察者盲法回顾性评分。
主要发现
- MRI方案判定为闭塞的病例均经DSA确认。
- 两位观察者分别将26例和28例AVM判为通畅,其中经DSA证实者分别为22例(85%)和22例(79%)。
- ASL在所有MRI序列中敏感度最高;3例患者中,ASL是唯一被1位观察者正确显示残留巢的序列。
- 标准化MRI方案检测残留巢的敏感度为100/100%,特异度为86/79%。
- 观察者间一致性极佳(κ=0.92,0.81-1.00)。
关键数值与推荐
- 以DSA为金标准,标准化MRI方案检测残留巢的敏感度为100/100%,特异度为86/79%。
- 观察者间一致性κ=0.92(0.81-1.00)。
- 末次随访时70%的AVM完全闭塞。
临床怎么用
- 对放射外科治疗后的脑AVM,可采用含ASL的标准化MRI方案无创评估巢内闭塞,高度敏感地检出残留巢。
- ASL可作为MRI方案中敏感度最高的序列,辅助判断残留巢。
局限性
- 单中心前瞻性研究,样本量为50例。
- 第二位观察者为回顾性盲法评分。
- 部分MRI判为通畅的病例经DSA未证实残留,特异度存在观察者间差异(86/79%)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVES: The gold standard for the evaluation of brain arteriovenous malformation (AVM) nidus occlusion after stereotactic radiosurgery is digital subtraction angiography (DSA), which is an invasive technique. We evaluated the role of MRI, especially arterial spin labeling (ASL) in the assessment of nidus occlusion after radiosurgery. DSA was used as the gold standard for comparison. METHODS: Fifty radiosurgically treated brain AVMs were included in this prospective single-center study. All patients underwent a standardized MRI protocol including following sequences: 2-dimensional T2w (TSE) in 3 planes, T1-weighted Magnetization Prepared Rapid Gradient Echo (MPRAGE), axial resolve diffusion-weighted imaging, ASL, time of flight, and time-resolved angiography with interleaved stochastic trajectories. Nidus obliteration according to the standardized MRI protocol was evaluated by an experienced neuroradiologist within 3 days after image acquisition and before DSA was subsequently performed as the reference standard. A second observer retrospectively rated MRI images of all 50 cases blinded to clinical and DSA data after the prospective study was concluded. RESULTS: All cases rated as obliterated by the MRI protocol were confirmed by DSA. However, 26 and 28 AVMs were rated as patent by the observers, which was verified in 22 (85/79%) cases by DSA. ASL had the highest sensitivity among all MRI sequences. In 3 patients, ASL was the only sequence that correctly revealed a residual nidus according to 1 observer. Overall, the sensitivity and specificity of the standardized MRI protocol for detection of a residual nidus were 100/100% and 86/79%, respectively. The interobserver agreement was excellent (κ = 0.92, 0.81-1.00). At last follow-up of this prospective study, 70% of AVMs were completely obliterated. CONCLUSION: MRI evaluation of nidus occlusion including ASL is highly sensitive for residual nidus detection and has a high potential to replace invasive DSA examinations for patients who underwent radiosurgery of brain AVMs.
引用
- Hirschmann D, Marik W, Cho A, et al. Evaluation of Nidus Occlusion After Radiosurgery in Brain Arteriovenous Malformations-A Prospective Study Using Arterial Spin Labeling. Neurosurgery. 2025. PMID: 40576348. doi:10.1227/neu.0000000000003590
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。