FLOW800联合多模态融合神经导航辅助脑动静脉畸形显微切除
OBJECTIVE: To assess the safety and effectiveness of combining indocyanine green videoangiography with FLOW800 and multimodal fusion neuro-navigation in brain arteriovenous malformation (AVM) microsurgical resection.…
要点
- 联合组术后Hb和HCT下降幅度小于未联合组
- 联合组出院时和6个月随访无残疾比例更高
- 联合组再手术率和术后并发症发生率更低
核心结论
- 联合应用术中吲哚菁绿视频血管造影(FLOW800)与多模态融合神经导航可减少脑动静脉畸形显微手术出血并改善功能结局。
主要发现
- 联合组术后Hb和HCT下降幅度小于未联合组。
- 联合组出院时和6个月随访无残疾比例高于未联合组。
- 联合组再手术率和术后并发症发生率低于未联合组。
临床怎么用
- 对脑动静脉畸形显微切除患者,可考虑联合术中吲哚菁绿视频血管造影(FLOW800)与多模态融合神经导航以辅助切除。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To assess the safety and effectiveness of combining indocyanine green videoangiography with FLOW800 and multimodal fusion neuro-navigation in brain arteriovenous malformation (AVM) microsurgical resection. METHODS: From January 1, 2019 to December 31, 2022, 90 consecutive patients at The First Affiliated Hospital of Soochow University diagnosed with AVMs were included. Patients were divided into a combined treatment group and a noncombined treatment group based on the treatment received. Clinical data including baseline characteristics, image findings, modified Rankin Score, and preoperation and postoperation hemoglobin (Hb)/hematocrit (HCT) levels were reviewed and collected for statistical analysis. RESULTS: Compared with the noncombined treatment group, the combined treatment group demonstrated a smaller postoperative decline in Hb and HCT levels after operation and a higher proportion of patients with no disability at discharge and at the 6-month follow-up. Additionally, the combined treatment group had lower rates of reoperation and postoperative complications. Compared with the noncombined treatment group, the combined treatment group demonstrated a smaller postoperative decline in Hb and HCT levels and a higher proportion of patients with no disability at discharge and at the 6-month follow-up. Additionally, the combined treatment group had lower rates of reoperation and postoperative complications. CONCLUSIONS: The combined utilization of intraoperative indocyanine green videoangiography with FLOW800 and multimodal fusion neuro-navigation appears to reduce intraoperative blood loss and enhance functional outcomes in AVM microsurgery, thereby improving both the safety and efficacy of the procedure.
引用
- Yang X, Tao X, Meng J, et al. Intraoperative Indocyanine Green Videoangiography with FLOW800 and Multimodal Fusion Neuro-Navigation for the Resection of Arteriovenous Malformation with Reduced Blood Loss. World Neurosurg. 2025. PMID: 40541664. doi:10.1016/j.wneu.2025.124193
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。