文献速递脑血管病外科神经重症

恶性大脑中动脉梗死去骨瓣减压术后颅内压动力学、脑自动调节与脑灌注:有创监测是否有作用?

Intracranial pressure dynamics, cerebral autoregulation, and brain perfusion after decompressive craniectomy in malignant middle cerebral artery infarction: is there a role for invasive monitoring?
PubMed 文献 · Acta Neurochir (Wien) · 2025-05-09

该回顾性研究纳入70例接受去骨瓣减压术且颅内压监测至少12小时的恶性大脑中动脉梗死患者,分析术后7天内颅内压、压力反应指数、脑灌注压及最佳灌注压偏差与6个月改良Rankin量表预后的关联。结果显示颅内压高于15 mmHg、压力反应指数超过0、脑灌注压低于80 mmHg及负的最佳灌注压偏差与不良预后相关,有创监测可能提供长期恢复的预后信息。

要点

  • 颅内压高于15 mmHg与不良预后相关,持续时间越长预后越差。
  • 压力反应指数超过0预后逐渐恶化,超过0.5与不良预后相关且与持续时间无关。
  • 脑灌注压低于80 mmHg时预后由良好转为不良,负的最佳灌注压偏差尤其低于-20 mmHg对应不良预后。

核心结论

  • 有创颅内压监测可能为恶性大脑中动脉梗死去骨瓣减压术后患者的长期恢复提供预后信息。
  • 研究强调了颅内压、压力反应指数、脑灌注压和最佳灌注压偏差的疾病特异性最佳生理区间。
  • 自动调节变量压力反应指数影响颅内压、脑灌注压和最佳灌注压偏差的安全与危险区间。

研究设计与样本

  • 回顾性研究纳入70例接受去骨瓣减压术的恶性大脑中动脉梗死患者,颅内压监测至少12小时且具备6个月改良Rankin量表预后数据。
  • 分析术后7天内颅内压、压力反应指数、脑灌注压及最佳灌注压偏差与改良Rankin量表的关联,并以热图呈现。

主要发现

  • 颅内压高于15 mmHg与不良预后相关,持续时间越长关联越明显。
  • 压力反应指数超过0时预后逐渐恶化,超过0.5与不良预后相关且与持续时间无关。
  • 脑灌注压低于80 mmHg时预后由良好转为不良。
  • 负的最佳灌注压偏差尤其低于-20 mmHg对应不良预后。
  • 双变量热图显示压力反应指数升高合并高颅内压、低脑灌注压或负的最佳灌注压偏差与更差预后相关。

关键数值与推荐

  • 颅内压高于15 mmHg与不良预后相关。
  • 压力反应指数超过0.5与不良预后相关,且与持续时间无关。
  • 脑灌注压低于80 mmHg时预后由良好转为不良。
  • 最佳灌注压偏差低于-20 mmHg对应不良预后。

临床怎么用

  • 去骨瓣减压术后可考虑有创颅内压监测,结合压力反应指数、脑灌注压和最佳灌注压偏差进行多参数评估。
  • 关注颅内压高于15 mmHg、压力反应指数超过0.5、脑灌注压低于80 mmHg及最佳灌注压偏差低于-20 mmHg等与不良预后相关的生理阈值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Malignant middle cerebral artery infarction (MMI) is a severe neurological condition. Decompressive craniectomy (DC) is an established lifesaving surgical treatment. However, the role of neurocritical care with monitoring and management of the intracranial pressure (ICP), pressure reactivity index (PRx), cerebral perfusion pressure (CPP), and optimal perfusion pressure (CPPopt) remain unclear. This study aims to examine the dynamics of these variables post-DC in relation to clinical outcome. METHODS: This retrospective study included 70 MMI patients who underwent DC with ICP monitoring of at least 12 hours and available data of clinical outcome (modified Rankin Scale [mRS] at 6 months). The associations between mRS and cerebral physiology (ICP, PRx, CPP, and ∆CPPopt) was analysed and presented in different outcome heatmaps over the first 7 days following DC. RESULTS: ICP above 15 mmHg was associated with unfavourable outcome, particularly for longer durations. As PRx exceeded zero, outcome worsened progressively, and values above 0.5 correlated to poor outcome regardless of duration. As CPP dropped below 80 mmHg, there was a transition from favourable to unfavourable outcome. Negative ∆CPPopt, particularly below -20 mmHg, corresponded to unfavourable outcome. In two-variable heatmaps, elevated PRx combined with high ICP, low CPP or negative ∆CPPopt correlated with worse outcome. CONCLUSION: Invasive ICP-monitoring may provide prognostic information for long-term recovery in MMI patients post-DC. The study highlighted disease-specific optimal physiological intervals for ICP, PRx, CPP, and ΔCPPopt. Of particular interest, the autoregulatory variable, PRx, influenced the safe and dangerous ICP, CPP, and ∆CPPopt intervals.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Alhamdan M, Hånell A, Howells T, et al. Intracranial pressure dynamics, cerebral autoregulation, and brain perfusion after decompressive craniectomy in malignant middle cerebral artery infarction: is there a role for invasive monitoring? Acta Neurochir (Wien). 2025. PMID: 40343533. doi:10.1007/s00701-025-06537-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。