脑室外引流患者近端与远端脑脊液采样部位比较
结果显示远端采样在白细胞计数上具有良好一致性(ICC 0.731),在乳酸、葡萄糖和总蛋白上一致性优秀,微生物培养完全一致。
要点
- 远端脑脊液采样与近端采样在白细胞计数上一致性良好(ICC 0.731)。
- 乳酸、葡萄糖和总蛋白的ICC分别为0.966、0.822和0.910,一致性优秀。
- 微生物培养结果完全一致,且一致性在留置超过4周时仍维持。
核心结论
- 远端脑脊液采样是近端采样的可靠替代方法,白细胞计数一致性良好,乳酸、葡萄糖和蛋白一致性优秀,培养完全一致,即使EVD留置超过4周。
主要发现
- 白细胞计数的ICC为0.731(95%CI:0.650-0.796)。
- 乳酸ICC为0.966,葡萄糖ICC为0.822,总蛋白ICC为0.910。
- 微生物培养结果完全一致,上述关系在超过4周时仍维持。
- 感染性样本数量较少(n=10)。
关键数值与推荐
- 白细胞计数ICC 0.731(95%CI:0.650-0.796)。
- 乳酸ICC 0.966,葡萄糖ICC 0.822,总蛋白ICC 0.910。
- 微生物培养结果完全一致。
临床怎么用
- 在EVD患者中可考虑采用远端脑脊液采样替代近端采样,以降低医源性感染、出血和导管阻塞风险。
局限性
- 感染性样本数量较少(n=10)。
- 单中心研究设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVES: Routine cerebrospinal fluid (CSF) sampling in patients with external ventricular drains (EVDs) is a standard neurosurgical practice to screen for infections and steer CSF diversion management. Although proximal CSF sampling (through CSF aspiration from the tubing) permits analysis of fresh intraventricular CSF, it carries a risk of iatrogenic infection, hemorrhage, and catheter blockage, contrary to distal CSF sampling (collected passively from the fluid chamber). This study assesses the agreement in CSF characteristics obtained through proximal and distal sampling in EVD patients. METHODS: An open, prospective, monocentric study was conducted between January 2022 and December 2023. All patients undergoing EVD placement were eligible. CSF was sampled twice weekly until EVD removal as per routine institutional practice. Samples were obtained synchronically proximally and distally. The primary end point was the agreement between sampling methods of the white cell count as quantified using the intraclass correlation (ICC), the within SD, and mean absolute difference. Secondary end points were the intermethod agreement of lactate, glucose, total protein, and microbial culture and the evaluation of the agreement over time. RESULTS: Sixty-one patients (2 × 197 samples) were analyzed. An ICC of 0.731 (95% CI: 0.650-0.796) was observed for white blood cell counts between proximal and distal samples. Microbial culture results showed perfect agreement. Strong ICCs were found for lactate (0.966), glucose (0.822), and total protein (0.910). These relations were maintained over time (>4 weeks). Although there were a relatively small number of infectious samples (n = 10), study strengths were the real-world setting, inclusion of all ages and etiologies, and longitudinal sampling over time. CONCLUSION: Distal CSF sampling is a reliable alternative to proximal CSF sampling, with a good ICC for white blood cell count; an excellent ICC for lactate, glucose, and protein; and a perfect ICC for culture, even in EVDs >4 weeks in place.
引用
- Deleu T, Bruyninckx D, Fieuws S, et al. A Comparison Between Proximal and Distal Cerebrospinal Fluid Sampling Sites in Patients With External Ventricular Drains. Neurosurgery. 2025. PMID: 40314442. doi:10.1227/neu.0000000000003482
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。