文献速递神经重症脑血管病外科

使用卷积神经网络算法在外部验证数据集上估算脑室内和颅内出血体积及中线移位

Estimation of Ventricular and Intracranial Hemorrhage Volumes and Midline Shift on an External Validation Data Set Using a Convolutional Neural Network Algorithm.
PubMed 文献 · Neurosurgery · 2025-04-14

本研究为单中心外部验证,纳入30例考虑行脑室外引流的颅内出血患者共78次扫描,评估人工智能算法Viz ICH-Plus自动定量颅内出血体积、双侧侧脑室体积及中线移位的性能,并与手动测量比较。结果显示各指标中位绝对误差分别为2.9 mL、5.3 mL和1.1 mm,检测临床有意义变化的敏感度、特异度、阳性预测值、阴性预测值和总体准确率分别为91.7%、92.6%、84.6%、96.2%和92.3%。

要点

  • Viz ICH-Plus定量颅内出血体积的中位绝对误差为2.9 mL(IQR 1.2至5.8)。
  • 双侧侧脑室体积和中线移位的中位绝对误差分别为5.3 mL(IQR 2.5至7.9)和1.1 mm(IQR 0.7至2.0)。
  • 检测临床有意义变化的敏感度91.7%、特异度92.6%、总体准确率92.3%。

核心结论

  • Viz ICH-Plus算法在量化颅内出血、双侧侧脑室体积和中线移位方面表现中等,人工智能与手动分割的空间重叠令人满意;使用预定阈值估计临床有意义变化时显示出良好的预测能力。

研究设计与样本

  • 单中心外部验证研究,纳入考虑行脑室外引流且初始非增强头颅CT及48小时内至少1次随访扫描的颅内出血患者30例,共78次扫描。

主要发现

  • 颅内出血体积中位绝对误差2.9 mL(IQR 1.2至5.8),双侧侧脑室体积5.3 mL(IQR 2.5至7.9),中线移位1.1 mm(IQR 0.7至2.0)。
  • 检测临床有意义变化(颅内出血体积增长≥10 mL、双侧侧脑室体积变化≥10 mL或中线移位增加≥4 mm)的敏感度91.7%、特异度92.6%、阳性预测值84.6%、阴性预测值96.2%、总体准确率92.3%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: Noncontrast head computed tomography is the mainstay imaging modality to guide the management of intracranial hemorrhage (ICH); however, manual measurements can be time-consuming. In our study, we evaluate the performance of an artificial intelligence (AI) machine learning algorithm, Viz ICH-Plus, to automatically quantify ICH and bilateral lateral ventricular (BLV) volumes as well as midline shift (MLS). METHODS: ICH patients considered for external ventricular drain with an initial noncontrast head computed tomography, and at least 1 follow-up scan within 48 hours was identified from a single center. Viz ICH-Plus estimations of ICH volume, BLV volume, and MLS were generated for each scan and compared with manually contoured and measured values. Median absolute errors and the ability of Viz ICH-Plus to detect clinically meaningful change from initial to follow-up scans (ICH volume growth ≥10 mL, BLV volume change ≥10 mL, or MLS increase ≥4 mm) were assessed. RESULTS: Thirty patients were included for a total of 78 scans. The median absolute error was 2.9 mL (IQR 1.2 to 5.8) for ICH, 5.3 mL (IQR 2.5 to 7.9) for BLV volume, and 1.1 mm (IQR 0.7 to 2.0) for MLS. The ability of Viz ICH-Plus to detect a clinically significant change between scans was robust with sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of 91.7%, 92.6%, 84.6%, 96.2%, and 92.3%, respectively. CONCLUSION: The described Viz ICH-Plus algorithm performed moderately well at quantifying ICH, BLV volume, and MLS with satisfying spatial overlap of artificial intelligence and manual segmentations. The system demonstrated good predictive power when using predetermined thresholds to estimate clinically significant changes.

来源:Neurosurgery,查看原文。版权归原作者所有。

引用

  1. Colasurdo M, Amran D, Chen H, et al. Estimation of Ventricular and Intracranial Hemorrhage Volumes and Midline Shift on an External Validation Data Set Using a Convolutional Neural Network Algorithm. Neurosurgery. 2025. PMID: 40227036. doi:10.1227/neu.0000000000003455

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。