重新审视Härtel技术用于经卵圆孔甘油注射
本研究基于11例三叉神经痛患者的CT与MRI模拟,重新审视Härtel经卵圆孔甘油注射技术,确定面颊部最佳进针点及经卵圆孔至Meckel腔的轨迹。最佳进针点位于口角水平面下2 mm、下颌支前缘前方,较Härtel原进针点低约10 mm;经卵圆孔内侧部可轻松到达Meckel腔(22侧中17侧)。作者认为优化进针点、透视下经卵圆孔内侧部引导穿刺并减少面颊软组织移动可改善技术结果。
要点
- 最佳进针点位于口角水平面下2 mm、下颌支前缘前方,较Härtel原进针点低约10 mm。
- 经卵圆孔内侧部可轻松到达Meckel腔,22侧中17侧成功。
- 作者建议选择最佳进针点、透视下经卵圆孔内侧部引导穿刺并减少面颊软组织移动。
核心结论
- 作者认为,若选择最佳进针点、在透视下经卵圆孔内侧部引导穿刺并尽量减少面颊软组织移动,经卵圆孔甘油注射的技术结果可得到改善。
研究设计与样本
- 基于影像的模拟研究,纳入11例因三叉神经痛转诊的患者,利用CT和MRI模拟确定面颊部最佳进针点及经卵圆孔至Meckel腔的轨迹,并与Härtel原始研究结果进行比较。
主要发现
- 最佳进针点位于经口角的水平面下2 mm、下颌支前缘正前方。
- 该进针点位于Härtel首选进针点下方约10 mm处,经卵圆孔内侧部可轻松到达Meckel腔,22侧中17侧成功。
关键数值与推荐
- 最佳进针点:口角水平面下2 mm、下颌支前缘前方;该点约在Härtel首选进针点下方10 mm。
- 经卵圆孔内侧部到达Meckel腔:22侧中17侧成功。
临床怎么用
- 作者建议选择最佳进针点、在透视下经卵圆孔内侧部引导穿刺并尽量减少面颊软组织移动。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Percutaneous transoval glycerol injection (GI) has been widely used since 1981 in the treatment of patients with trigeminal neuralgia. However, outcomes have been more variable than with other percutaneous treatments. Although most authors state that they use Härtel's technique, the variations are numerous-which may explain procedural problems and most of the poor results. The aim of the present imaging-based study, therefore, was to revisit Härtel's technique and identify optimal landmarks for guiding the needle from the cheek to Meckel's cave. METHODS: Eleven patients referred for trigeminal neuralgia were studied. We used CT- and MRI-based simulations to determine the optimal entry points in the cheek and trajectories through foramen ovale (FO) to reach Meckel's cave - and compared our findings with the results from Härtel's original study. RESULTS: The optimal entry point was located at 2 mm below the horizontal plane through the angle of the mouth and just in front of the anterior edge of the mandibular ramus. From this entry point-situated around 10 mm below Härtel's preferred entry point-Meckel's cave was easily accessible through the medial part of FO in 17 of 22 sides. CONCLUSION: The findings from this study suggest that the technical results of transoval glycerol injection can be improved if we 1. Select the optimal entry point, 2. Guide the needle under fluoroscopy through the medial part of the foramen ovale, and 3. Minimize movement of the soft tissues in the cheek.
引用
- Slettebø H, Sakinis T. Revisiting Härtel's technique for percutaneous transoval glycerol injection. Acta Neurochir (Wien). 2025. PMID: 40304736. doi:10.1007/s00701-025-06526-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。