基于磁共振成像的影像组学鉴别早期非典型原发性中枢神经系统淋巴瘤与低级别胶质瘤
本研究回顾性纳入四川大学华西医院(PCNSL=75,LGG=138)和成都上锦南府医院(PCNSL=35,LGG=72)两个队列,构建基于MRI的影像组学模型以鉴别早期非典型PCNSL与影像表现相似的低级别胶质瘤,最佳模型在独立外部验证集上AUC为0.929(0.901-0.957),准确率为91.6%。
要点
- 基于MRI的影像组学模型可准确鉴别早期非典型PCNSL与影像表现相似的LGG。
- 最佳模型在独立外部验证集上AUC为0.929(0.901-0.957),准确率为91.6%。
- 纳入19例典型或晚期PCNSL患者的早期非典型病灶作为补充可提升模型性能。
核心结论
- 基于MRI的影像组学模型能准确鉴别早期非典型PCNSL与影像表现相似的LGG,使早期非典型PCNSL患者及时接受放疗或化疗,同时避免不必要的手术切除。
研究设计与样本
- 回顾性纳入四川大学华西医院早期非典型PCNSL患者75例和影像表现相似的LGG患者138例作为训练集,成都上锦南府医院PCNSL患者35例和LGG患者72例作为外部验证集,训练集另纳入19例典型或晚期PCNSL患者的早期非典型病灶作为补充。
主要发现
- 共筛选出9个影像组学特征作为显著特征,其中大多数为小波影像组学特征。
- 最佳影像组学模型在独立外部验证集上的AUC为0.929(0.901-0.957),准确率为91.6%。
- 纳入19例额外PCNSL患者后模型性能得到提升。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Different from typical primary central nervous system lymphoma (PCNSL), early-stage atypical PCNSL usually presents as patchy signal abnormalities without evident mass effect or significant contrast enhancement and is prone to confusion with low-grade glioma (LGG). This study aims to develop a magnetic resonance imaging (MRI)-based radiomics model to differentiate early-stage atypical PCNSL from LGG. METHODS: Two cohorts consisting of early-stage atypical PCNSL patients, as well as LGG patients with similar radiological manifestations, were retrospectively recruited from West China Hospital of Sichuan University (PCNSL = 75; LGG = 138) and Chengdu Shangjin Nanfu Hospital (PCNSL = 35; LGG = 72) to serve as the training set and external validation set, respectively. Within the training set, there were additional early-stage atypical lesions from 19 typical or advanced-stage PCNSL patients included as a supplement. MRI-based radiomics models were developed and validated based on these 2 cohorts. RESULTS: Nine radiomic features were selected as significant features, most of which are wavelet radiomic features. The best radiomics model achieved an area under the curve of 0.929 (0.901-0.957) and an accuracy of 91.6% on the independent external validation set. The inclusion of 19 additional PCNSL patients improved the model's performance. CONCLUSIONS: The MRI-based radiomics model can accurately differentiate early-stage atypical PCNSL from LGG with similar radiological manifestations, allowing early-stage atypical PCNSL patients to receive timely and appropriate radiotherapy or chemotherapy while avoiding unnecessary surgical resection.
引用
- Zhao K, Deng Y, Su X, et al. Differential Diagnosis of Early-Stage Atypical Primary Central Nervous System Lymphoma and Low-Grade Glioma Using Magnetic Resonance Imaging-Based Radiomics. World Neurosurg. 2025. PMID: 39929267. doi:10.1016/j.wneu.2025.123740
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。