慢性硬膜下血肿中脑膜中动脉的超声血流动力学研究
本研究收集100例慢性硬膜下血肿(CSDH)患者临床资料,其中87例行钻孔引流术,另选80名健康志愿者和60例急性硬膜下血肿患者为对照,采用彩色多普勒超声(CDUS)经颞下窝半张口位检测脑膜中动脉(MMA)血流动力学。结果显示CSDH组、健康对照组和急性硬膜下血肿组MMA显示率分别为84.43%(103/122)、85.00%(136/160)和83.33%(70/84);多因素logistic回归提示双侧血肿、收缩期峰值流速(PSV)升高和阻力指数(RI)降低是钻孔引流术后复发的独立危险因素(P<0.05)。
要点
- 半张口位CDUS评估颅外MMA可行,CSDH组显示率84.43%(103/122)。
- 双侧血肿、PSV升高、RI降低是CSDH钻孔引流术后复发的独立危险因素(P<0.05)。
- PSV预测值30.85 cm/s、RI预测值0.78时约登指数最大。
核心结论
- 半张口位CDUS是评估颅外MMA的可行方法,监测CSDH术后MMA血流动力学变化对提示术后复发风险有重要价值。
研究设计与样本
- 研究收集2023年1月至2024年3月本院收治的100例CSDH患者临床资料,其中87例行钻孔引流术,术后随访分为复发组和非复发组;另选80名健康志愿者和60例急性硬膜下血肿患者为对照组。
- 采用CDUS技术经颞下窝半张口位评估MMA,获取PSV、舒张末期流速和RI。
主要发现
- CSDH组MMA显示率为84.43%(103/122),健康志愿者组为85.00%(136/160),急性硬膜下血肿组为83.33%(70/84)。
- 多因素logistic回归分析显示,双侧血肿、PSV升高和RI降低是CSDH钻孔引流术后复发的独立危险因素(P<0.05)。
- PSV预测值为30.85 cm/s、RI预测值为0.78时约登指数最大。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To explore the feasibility of color Doppler ultrasound (CDUS) in detecting the middle meningeal artery (MMA) and evaluate the clinical application of this method in chronic subdural hematoma (CSDH). METHODS: This study collected clinical data from 100 patients with CSDH who were admitted to our hospital between January 2023 and March 2024. Among these patients, 87 underwent drilling and drainage surgery. Postoperative follow-up categorized patients into a recurrence group and a nonrecurrence group. Additionally, 80 healthy volunteers and 60 patients with acute subdural hematoma were selected as the control group. Using CDUS technology, the MMA was assessed through the infratemporal fossa in the half-mouth position to obtain peak systolic flow velocity (PSV), end diastolic flow velocity, and resistance index (RI). Comparisons were conducted between the study group and the control group, as well as between the recurrence and nonrecurrence groups to evaluate hemodynamic differences. Multivariate logistic regression analysis was employed to identify risk factors for postoperative recurrence in patients with CSDH. Receiver operating characteristic curves were generated to assess the sensitivity and specificity of MMA hemodynamic parameters in predicting postoperative recurrence of CSDH. RESULTS: The MMA visualization rates for the CSDH group, healthy volunteer group, and acute subdural hematoma group were 84.43% (103/122), 85.00% (136/160), and 83.33% (70/84), respectively. Multivariate logistic regression analysis indicated that bilateral hematoma, increased PSV, and decreased RI were independent risk factors for the recurrence of CSDH following drilling and drainage (P < 0.05). The maximum Youden index was achieved when the PSV predictive value was 30.85 cm/s and the RI predictive value was 0.78. CONCLUSIONS: Utilizing CDUS in a half-open mouth position is a feasible method for evaluating extracranial MMA. Monitoring hemodynamic changes in the MMA of patients with CSDH postsurgery holds significant value in indicating the potential for postoperative recurrence.
引用
- Wang X, Liu Z, Qi T, et al. Ultrasonic Hemodynamics of Middle Meningeal Artery in Chronic Subdural Hematoma. World Neurosurg. 2025. PMID: 39956373. doi:10.1016/j.wneu.2025.123793
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。